Goodman Mfg GPH14H Heat Pump User Manual


 
Product sPecifications
Product sPecifications
SS-GPH14H www.goodmanmfg.com 3
sPecifications
GPH14
24H41A*
GPH14
30H41A*
GPH14
36H41A*
GPH14
42H41A*
GPH14
48H41A*
GPH14
60H41A*
CoolinG CAPACity
AHRI Cooling Capacity (BTU/h)
24,400 29,600 36,000 40,000 46,000 57,000
Sensible BTU/h
18,200 23,400 27,400 29,600 35,400 40,500
SEER / EER
15.0 / 12.2 14.5 / 12.2 14.3 / 12 14.2 / 12 14.5 / 12.1 14.2 / 12
Decibels
76 76 78 78 80 80
AHRI Numbers
4385132 4385133 4385134 4385135 4385136 4385137
HeAtinG CAPACity
BTU/h (47°F)
22,800 27,600 33,000 37,600 45,000 54,500
C.O.P. (47°F)
3.8 3.8 3.7 3.8 3.9 3.6
BTU/h (17°F)
13,000 15,400 21,400 21,600 26,000 33,800
C.O.P. (17°F)
2.4 2.5 2.4 2.4 2.4 2.5
HSPF
8.0 8.3 8.5 8.3 8.3 8.4
evAPorAtor Motor
Type
EEM EEM EEM EEM EEM EEM
Wheel (D x W)
10 x 8 10 x 8 10 x 8 10 x 8 10 x 8 11 x 8
Cooling CFM
850 1,050 1,200 1,300 1,600 1,600
Fan-Only CFM
800 950 1,100 1,200 1,400 1,600
RLA
1.5 1.86 1.86 2.9 2.9 2.9
No. of Speeds
5 5 5 5 5 5
Horsepower - RPM
½ - 1,050 ½ - 1,050 ½ - 1,050 ½ - 1,050 ¾ - 1,050 ¾ - 1,050
evAPorAtor Coil
Face Area (ft
2
)
5.25 4.67 5.2 6.2 6.2 7.0
Rows Deep/ Fins per Inch
3/ 16 4/ 16 3/ 14 4/ 14 4/ 14 4/ 14
Indoor Metering Device Size
0.057 0.065 0.068 0.072 0.076 0.088
Filter Size (ft
2
)
20 x 20 x 1 20 x 25 x 1 25 x 25 x 1 (2) 20 x 20 x 1 (2) 20 x 20 x 1 (2) 20 x 25 x 1
Drain Size (NPT)
¾" ¾" ¾" ¾" ¾" ¾"
Refrigerant Charge (oz.)
85 105 125 150 190 200
Condenser FAn / Coil
Horsepower - RPM
1/6 - 815 1/6 - 815 ¼ - 1075 ¼ - 1075 ¼ - 1075 ¼ - 1075
RLA/LRA
1.1 / 1.7 1.1 / 1.7 1.5 /3.0 1.4 / 2.9 1.4 / 2.9 1.4 / 2.9
Fan Diameter / # Fan Blades
22 / 3 22 / 3 22 / 4 22 / 4 22 / 4 22 / 4
Face Area (ft
2
)
13.4 13.4 17 17 19.1 19.1
Outdoor Metering Device Size
0.049 0.047 0.067 0.065 0.065 0.071
Rows Deep/ Fins per Inch
1 / 24 1 / 24 1 / 24 1 / 24 2 / 16 2 / 16
CoMPressor
Quantity
1 1 1 1 1 1
Type
Scroll Scroll Scroll Scroll Scroll Scroll
Stage
Single Single Single Single Single Single
eleCtriCAl dAtA
Voltage/Phase/ Frequency
208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Compressor RLA/LRA
12.8 / 58.3 14.1 / 73 16.7 / 79 17.9 / 112 19.9 / 109 26.4 / 134
Indoor Blower FLA
1.5 1.86 1.86 2.9 2.9 2.9
Outdoor Fan RLA
1.1 1.1 1.4 1.4 1.4 1.4
Total Unit Amps
15.4 17.06 19.96 22.2 24.2 30.7
Min. Circuit Ampacity¹
18.6 20.6 24.2 26.6 29.2 40.2
Min. Overcurrent Protection (amps)²
30 30 40 40 45 60
sHiP WeiGHt (lbs)
325 325 385 385 415 415
oPerAtinG WeiGHt (lbs)
315 315 375 375 405 405
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.