Goodman Mfg GPC13M Air Conditioner User Manual


 
P
RODUCT
S
PECIFICATIONS
6 www.goodmanmfg.com SS-GPC13M-SP
VALORES DE REFRIGERACIÓN EXPANDIDA GPC1336M21A
Temperatura Ambiente Externa
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Temperatura inicial del bulbo húmedo interno
IDB
Flujo de aire
59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
70
1378
MBh 34.3 35.5 38.9 - 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.9 33.1 36.2 - 30.3 31.4 34.4 - 28.1 29.1 31.9 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 -
kW 2.51 2.56 2.63 - 2.69 2.74 2.82 - 2.84 2.90 2.98 - 2.97 3.03 3.13 - 3.09 3.15 3.25 - 3.19 3.25 3.35 -
Amps 10.6 10.8 11.1 - 11.3 11.5 11.8 - 12.1 12.3 12.6 - 12.8 13.0 13.4 - 13.5 13.7 14.1 - 14.1 14.4 14.9 -
Hi PR 153 165 174 - 172 185 196 - 196 211 222 - 223 240 253 - 251 270 285 - 277 298 315 -
Lo PR 65 70 76 - 69 73 80 - 72 76 83 - 75 80 88 - 79 84 92 - 82 87 95 -
1225
MBh 33.3 34.5 37.8 - 32.5 33.7 36.9 - 31.7 32.9 36.1 - 31.0 32.1 35.2 - 29.4 30.5 33.4 - 27.3 28.3 31.0 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
kW 2.50 2.54 2.62 - 2.67 2.72 2.80 - 2.82 2.87 2.96 - 2.95 3.01 3.10 - 3.07 3.13 3.22 - 3.16 3.23 3.33 -
Amps 10.5 10.7 11.0 - 11.2 11.4 11.7 - 12.0 12.2 12.6 - 12.7 12.9 13.3 - 13.3 13.6 14.0 - 14.0 14.3 14.7 -
Hi PR 152 163 173 - 170 183 194 - 194 209 220 - 221 238 251 - 248 267 282 - 274 295 312 -
Lo PR 65 69 75 - 68 73 79 - 71 76 83 - 75 79 87 - 78 83 91 - 81 86 94 -
1072
MBh 30.7 31.9 34.9 - 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.6 32.5 - 27.2 28.2 30.8 - 25.2 26.1 28.6 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
T 18 16 12 - 18 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
kW 2.44 2.49 2.56 - 2.61 2.66 2.74 - 2.76 2.81 2.89 - 2.89 2.94 3.03 - 3.00 3.06 3.15 - 3.09 3.15 3.25 -
Amps 10.2 10.4 10.7 - 10.9 11.1 11.4 - 11.7 11.9 12.3 - 12.4 12.6 13.0 - 13.0 13.3 13.7 - 13.7 14.0 14.4 -
Hi PR 147 159 167 - 165 178 188 - 188 202 214 - 214 230 243 - 241 259 274 - 266 286 302 -
Lo PR 63 67 73 - 66 71 77 - 69 73 80 - 72 77 84 - 76 81 88 - 79 84 91 -
75
1378
MBh 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.3 34.2 37.1 39.8 32.4 33.4 36.2 38.8 30.8 31.7 34.4 36.9 28.6 29.4 31.8 34.2
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
T 20181510201915112019 15 11 20 19 15 11 20 18 15 10 19 17 14 10
kW 2.53 2.58 2.65 2.73 2.71 2.76 2.84 2.92 2.86 2.92 3.00 3.10 3.00 3.06 3.15 3.25 3.11 3.18 3.27 3.37 3.21 3.28 3.38 3.49
Amps 10.6 10.8 11.1 11.5 11.3 11.6 11.9 12.3 12.2 12.4 12.8 13.2 12.9 13.1 13.5 13.9 13.6 13.8 14.2 14.7 14.3 14.6 15.0 15.5
Hi PR 155 167 176 184 174 187 198 206 198 213 225 234 225 242 256 267 253 273 288 300 280 301 318 332
Lo PR 66 70 77 82 70 74 81 86 73 77 84 90 76 81 88 94 80 85 93 99 83 88 96 102
1225
MBh 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 32.3 33.2 36.0 38.6 31.5 32.4 35.1 37.7 29.9 30.8 33.3 35.8 27.7 28.5 30.9 33.2
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
T 21191611211916112119 16 11 21 20 16 11 21 19 16 11 20 18 15 10
kW 2.51 2.56 2.63 2.71 2.69 2.74 2.82 2.90 2.84 2.90 2.98 3.07 2.97 3.03 3.13 3.22 3.09 3.15 3.25 3.35 3.19 3.25 3.35 3.46
Amps 10.6 10.8 11.1 11.4 11.3 11.5 11.8 12.2 12.1 12.3 12.7 13.1 12.8 13.0 13.4 13.8 13.5 13.7 14.1 14.6 14.1 14.4 14.9 15.4
Hi PR 153 165 174 182 172 185 196 204 196 211 223 232 223 240 253 264 251 270 285 297 277 298 315 329
Lo PR 65 70 76 81 69 74 80 85 72 76 83 89 75 80 88 93 79 84 92 98 82 87 95 101
1072
MBh 31.3 32.2 34.8 37.4 30.5 31.4 34.0 36.5 29.8 30.7 33.2 35.6 29.1 29.9 32.4 34.8 27.6 28.4 30.8 33.0 25.6 26.3 28.5 30.6
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
T 21191611212016112120 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 2.46 2.51 2.58 2.65 2.63 2.68 2.76 2.84 2.78 2.83 2.91 3.00 2.91 2.97 3.05 3.15 3.02 3.08 3.17 3.27 3.11 3.18 3.27 3.38
Amps 10.3 10.5 10.8 11.1 11.0 11.2 11.5 11.9 11.8 12.0 12.4 12.7 12.5 12.7 13.1 13.5 13.1 13.4 13.8 14.2 13.8 14.1 14.5 15.0
Hi PR 149 160 169 176 167 180 190 198 190 204 216 225 216 233 246 256 243 262 277 288 269 289 306 319
Lo PR 63 67 74 78 67 71 78 83 70 74 81 86 73 78 85 91 77 82 89 95 79 84 92 98
IDB: Temperatura inicial del bulbo de secado interno El área sombreada re eja las condiciones ACCA (TVA) Amps = amperes de la unidad externa (comp.+ventilador)
Las presiones altas y bajas se miden en válvulas de servicio de succión y líquidas. kW = Energía total del sistema