PRoDucT sPeciFicATions
PRoDucT sPeciFicATions
SS-GMVM96 www.goodmanmfg.com 5
gcVM96 D
iMensions
FOLDED FLANGES
UNFOLDED FLANGES
FOLDED FLANGES
UNFOLDED FLANGES
MiniMuM cleARAnces To coMbusTible MATeRiAls
Downow 0” 0” 3” NC 0” 1”
Horizontal 6” 0” 3” C 0” 6”
C = If placed on combusble oor, the oor MUST be wood ONLY.
NC = For installaon on non-combusble oors only. A combusble oor sub-base must be used for installaons on combusble ooring.
• For servicing or cleaning, a 24” front clearance is required.
• Unit connecons (electrical, ue and drain) may necessitate greater clearances than the minimum clearances listed above.
• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
D H A B C D E
GCVM960604CX 21" 28¾" 40¾" 21" 19½” 16⅛" 18" 19½”
GCVM960805DX 24½” 28¾" 40¾" 24½” 23" 20⅝" 21½” 23"
GCVM961005DX 24½” 28¾" 40¾" 24½” 23" 20⅝" 21½” 23"
• Installer must supply one or two PVC pipes: one for combuson air (oponal) and one for the ue outlet (required). Vent pipe must be either 2” or
3” in diameter, depending upon furnace input, number of elbows, length of run, and installaon (1 or 2 pipes). The oponal Combuson Air Pipe is
dependent on installaon/code requirements and must be 2” or 3” diameter PVC.
• Line voltage wiring can enter through the right or le side of the furnace. Low-voltage wiring can enter through the right or le side of furnace.
• Conversion kits for high-altude natural gas operaon are available. Contact your Goodman distributor or dealer for details.
• Installer must supply following gas line ngs, according to which entrance is used:
Le—Two 90º elbows, one close nipple, straight pipe
Right—Straight pipe to reach gas valve
• For boom return: Failure to unfold anges may reduce airow by up to 18%. This could result in performance and noise issues.