The dehumidifier will turn off automatically when the bucket is
full, or when the bucket is removed or not replaced in the
proper position.
The bucket must be replaced in the proper position for the
dehumidifier to work. The light will be on and the dehumidifier
will not run if the bucket is not in the proper position.
Disposing of collected water
1. Empty the bucket manually.
When the bucket is full, pull out and
empty it into a large sink or tub and
then replace it properly.
NOTE: Do not overtighten the
hose when connecting it to the
bucket. Use a rubber washer and
tighten by hand firmly without
stripping the plastic threads.
NOTE:Be careful while taking out
the bucket as it can cause
damage.
NOTE:Please do not shake
strongly when you carry the
bucket. It can cause to breakage
of the handle or bucket cover.
It is advisable to carry the bucket
by supporting it from the bottom.
2.
The bucket has a threaded hose
connection which can be left open.
Drill a 1/4" (6.4 mm) hole in the
center of the hose connection.
Once opened, the hose connection
will continually drain water from the
bucket.
NOTE: The nozzle cannot be fixed
after puncture. Use an ordinary
garden hose cap to reclose if
necessary.
NOTE:When inserting the bucket
into the unit. lifting up the bottom
tip of the bucket lightly makes
insertion easily.
When being attached to the bucket
drain hose connection, be sure the
hose doesnt kink or bend. It should
lie flat from the dehumidifier to the
drain.
NOTE: The hose attachment will
accept a standard garden hose
filling. You can attach a screw-on
cap to use the bucket without a
hose.
Attach a length of garden hose to the threaded bucket drain hose
connection to carry water to the drain.