Goldstar DH3010B Dehumidifier User Manual


 
1. Remove the cabinet. (Refer to section 3.1.3)
2. Remove a screw or a nut which fastens the
terminal cover
3. Disconnect the lead wire from the overload
protector or P.T.C. assembly.
4. Remove the overload protector(O.L.P) or P.T.C.
assembly. (See Figure 20)
3.3.3 ROTARY COMPRESSOR
1. Remove the cabinet. (Refer to section 3.1.3)
2. Discharge the refrigerant by using a refrigerant
Recovery System.
3. After purging the unit completely, unbrace the
suction and discharge tubes at the compressor
connections.
4. Remove the nuts and washers which fasten the
compressor. (See Figure 21)
5. Remove the compressor. (See Figure 21)
14
Figure 20
Using Recipro Compressor model
Using Rotary Compressor models
Figure 21
3.3.2 P.T.C. OR OVERLOAD PROTECTOR (O.L.P.) FOR RECIPROCATING COMPRESSOR