Specifications
Model P217A-3100/5100
Consult the factory for special requirements that must be met if the pump is
to operate beyond one or more of the limits specified above.
U.S. (Metric)
1750 RPM
+
Ratings ......................................................... 1.8 GPM @ 2000 PSI ...... (6.8 LPM @ 137 bar)
3450 RPM
+
Ratings ......................................................... 3.3 GPM @ 2000 PSI ...... (12.5 LPM @ 137 bar)
Plunger Diameter.......................................... 4.76............................... 18mm
Stroke........................................................... 1.45............................... 5.5mm
Temperature of Pumped Fluids ..................... Up to 160
o
F ................... (71
o
C)
Inlet Ports .............................................................................................. (2) 3/8" BSP
Discharge Ports ..................................................................................... (2) 3/8" BSP
Shaft Rotation........................................................................................ Top of Pulley Towards Fluid End
Crankshaft Diameter..................................... 0.94............................... 24mm
Key Width .................................................... 0.31............................... 8mm
Shaft Mounting...................................................................................... Either Side
Weight.......................................................... 11 lbs. 11oz. .................... (4.9 kg)
Crankcase Oil Capacity ................................ 8.1 fl.oz........................... (0.24 liters)
Volumetric Efficiency @ 1750 RPM ...................................................... 0.90
Mechanical Efficiency @ 1750 RPM ..................................................... 0.88
*15 PSI inlet pressure required
PULLEY INFORMATION
Pulley selection and pump speed are based on a 1725
RPM motor and "B" section belts. When selecting
desired GPM, allow for a ±5% tolerance on pumps
output due to variations in pulleys, belts and motors
among manufacturers.
1. Select GPM required, then select appropriate
motor and pump pulley from the same line.
2. The desired pressure is achieved by selecting the
correct nozzle size that corresponds with the pump
GPM.
HORSEPOWER INFORMATION
Horsepower ratings shown are the power require-
ments for the pump. Gas engine power outputs must
be approximately twice the pump power require-
ments shown above.
We recommend that a 1.1 service factor be specified
when selecting an electric motor as the power source.
To compute specific pump horsepower requirements,
use the following formula:
GPM X PSI
=hp
1450
PUMP
PULLEY
MOTOR
PULLEY
RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI
7.75 4.00
1750 1.8 1.0 1.5 1.9 2.1 2.5
7.75 6.80
3000 3.0 1.7 2.5 3.1 3.5 4.1
7.75 7.25
3200 3.2 1.8 2.6 3.3 3.8 4.4
7.75 7.75
3450 3.3 1.8 2.7 3.4 3.9 4.6
P217A-3100/5100 PULLEY SELECTION & HORSEPOWER