Giant P219 Septic System User Manual


 
14
PUMP SYSTEM MALFUNCTION
MALFUNCTION
The Pressure and/or
the Delivery Drops
Water in crankcase
Noisy Operation
Rough/Pulsating
Operation with
Pressure Drop
Pressure Drop at
Gun
Excessive Leakage
High Crankcase
Temperature
CAUSE
Worn packing seals
Broken valve spring
Belt slippage
Worn or Damaged nozzle
Fouled discharge valve
Fouled inlet strainer
Worn or Damaged hose
Worn or Plugged relief valve on pump
Cavitation
Unloader
High humidity
Worn seals
Worn bearings
Cavitation
Worn packing
Inlet restriction
Accumulator pressure
Unloader
Cavitation
Restricted discharge plumbing
Worn plungers
Worn packing/seals
Excessive vacuum
Cracked plungers
Inlet pressure too high
Wrong Grade of oil
Improper amount of oil in crankcase
REMEDY
Replace packing seals
Replace spring
Tighten or Replace belt
Replace nozzle
Clean valve assembly
Clean strainer
Repair/Replace hose
Clean, Reset, and Replace worn parts
Check suction lines on inlet of
pump for restrictions
Check for proper operation
Reduce oil change interval
Replace seals
Replace bearings, Refill crankcase
oil with recommended lubricant
Check inlet lines for restrictions
and/or proper sizing
Replace packing
Check system for stoppage, air
leaks, correctly sized inlet plumbing
to pump
Recharge/Replace accumulator
Check for proper operation
Check inlet lines for restrictions
and/or proper size
Re-size discharge plumbing to
flow rate of pump
Replace plungers
Adjust or Replace packing seals
Reduce suction vacuum
Replace plungers
Reduce inlet pressure
Giant oil is recommended
Adjust oil level to proper amount