Giant P208 Water Pump User Manual


 
P208 HORSEPOWER REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI*
250 0.14 0.1 0.1 0.2 0.2
500 0.29 0.2 0.3 0.4 0.5
1000 0.57 0.4 0.6 0.8 1.0
1750 1.00 0.7 1.0 1.4 1.7
3000 1.60 1.1 1.7 2.2 2.8
3200 1.80 1.2 1.9 2.5 3.1
3450 1.90 1.3 2.0 2.6 3.3
5
Specifications
Model P208
NOTE:
In order to drive the pump from the side opposite the present shaft
extension, simply remove the valve casing from the crankcase and
rotate the pumps 180 degrees to the desired position. Be certain to
rotate the seal case (item #20) as well, so that the weep holes are
down at the six o'clock position. Exchange the oil fill and the oil
drain plugs, also. Refer to the repair instructions as necessary for
the proper assembly sequence.
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the
pump. Gas
engine power outputs must be
approximately twice the pump
power requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an
electric motor as the power source.
To compute specific pump horse
power requirements, use the
following formula:
HP = (GPM X PSI) / 1450
Consult the factory for special requirements that must be met if the pump is
to operate beyond one or more of the limits specified above.
1750 RPM
Ratings (Continuous).................................................................................. 1.0 GPM @ 2000 PSI
Ratings (Intermittent) ................................................................................. 1.0 GPM @ 2500 PSI*
3450 RPM
Ratings (Continuous).................................................................................. 1.9 GPM @ 2000 PSI
Ratings (Intermittent) ................................................................................. 1.9 GPM @ 2500 PSI*
Inlet Pressure .............................................................................................. up to 140 PSI
Plunger Diameter........................................................................................ 12mm
Stroke.......................................................................................................... 7mm
Temperature of Pumped Fluids .................................................................. Up to 160
o
F
Inlet Ports.................................................................................................... (2) 1/2" BSP
Discharge Ports ........................................................................................... (2) 3/8" BSP
Shaft Rotation ................................................................................ Top of Pulley Towards Fluid End
Crankshaft Diameter................................................................................... 24mm
Key Width................................................................................................... 8mm
Shaft Mounting ........................................................................................... Right Side Facing Manifold
Weight......................................................................................................... 11 lbs. 11oz.
Crankcase Oil Capacity .............................................................................. 7.5 fl.oz.
Extended Crankcase Oil Capacity .............................................................. 9.0 fl.oz.
Volumetric Efficiency @ 1750 RPM.......................................................... 0.94
Volumetric Efficiency @ 3450 RPM.......................................................... 0.88
Mechanical Efficiency @ 3450 RPM......................................................... 0.86