Giant CP218 Water Pump User Manual


 
CP218 HORSEPOWER REQUIREMENTS
RPM GPM 500 PSI 1000 PSI 1500 PSI 2030 PSI
200 0.4 0.1 0.3 0.4 0.6
300 0.6 0.2 0.4 0.6 0.8
400 0.7 0.2 0.5 0.7 1.0
500 0.9 0.3 0.6 0.9 1.3
600 1.1 0.4 0.8 1.1 1.5
750 1.4 0.5 1.0 1.4 2.0
3
NOTE:
In order to drive the pump from the side opposite the present shaft extension,
simply remove the valve casing from the crankcase and rotate the pumps 180
degrees to the desired position. Be certain to rotate the seal case (item #20) as
well, so that the weep holes are
down at the six o'clock position. Exchange the oil
fill and the oil drain plugs, also. Refer to the repair instructions as necessary for
the proper assembly sequence.
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the
pump. Gas
engine power outputs must be
approximately twice the pump
power requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an
electric motor as the power source.
To compute specific pump horse
power requirements, use the
following formula:
HP = (GPM X PSI) / 1450
Consult the factory for special requirements that must be met if the pump is
to operate beyond one or more of the limits specified above.
Specifications
Model CP218
Ratings ........................................................................................................ 1.4 GPM @ 2030 PSI
Inlet Pressure.............................................................................................. 14 to 140 PSI
RPM ........................................................................................................... Up to 750 RPM
Plunger Diameter........................................................................................ 18mm
Stroke.......................................................................................................... 10mm
Temperature of Pumped Fluids................................................................... -40
o
F to 160
o
F
Inlet Ports ................................................................................................... (2) 3/8" BSP
Discharge Ports .......................................................................................... (2) 3/8" BSP
Shaft Rotation ................................................................................ Top of Pulley Towards Fluid End
Crankshaft Diameter .................................................................................. 24mm
Key Width................................................................................................... 8m m
Shaft Mounting ........................................................................................... Right Side Facing Manifold
Weight ......................................................................................................... 11 lbs. 11oz.
Crankcase Oil Capacity .............................................................................. 7.5 fl.oz.
Extended Crankcase Oil Capacity.............................................................. 9.0 fl.oz.
+
Positive inlet pressure required