Warranty
10010 series
Standard Electromagnetic Lock
Optional Brackets
The door swinging direction and the door frame header are
used to determine whether the bracket is required and this
identify is a measure of which brackets is suitable. Our
optional brackets include L bracket LZ bracket and U
bracket (Except 10002BZ )
-,- -
.
With L-bracket for narrow door frames
Magnet
Armature
Door
Frame
Door
Leaf
60mm
A
Out-swinging
When <60mm,must
installed with "L" brackets.
"A"
L-500
With LZ-bracket for in-swinging doors
LZ-500N
Operating Features
10020TD: Re-locking timedelay
Relocking Time Delay Switch ensures
the automatically turns to lock mode
after the door is closed properly and it
can be adjustedfrom 0 to 90 seconds.
lll
N.O.
COM.
N.C.
Power
Input
SPDTrelay
3A@12VDC
TimerAdjust
Shorten
Trigger
10020BZ: BuzzerAlarm
Door Held Open Alarm is an auditory feedback for
user.Alarm sounds when the door is not closed and
has exceeded a specified time limit. Only way to
stop is by the unclosing door has been closed
correctly. User can also configure alarm time limit
settings on the VR timer and it is adjustable from 0
to 20seconds.
10020: Bond sensor output & Status LED
Bond sensor is used to indicate the door
status as in a locked or unlocked condition.
is a visual feedback for user to
give the true status of the lock at any time.
Green light indicates the door is insecure
Status LED
Bond sensormonitor output : SPDTrated: 3A@12VDC
: Door statusand bond sensor output
& Status LED
10020DS
Door Status Sensor indicates the door is in an
opened or closed status. Magnetic Bond Sensor
indicatesthedoorisinalockedorunlockedstatus.
output :SPDT rated: 0.25A@12VDCDoor status