Gentek CO1209 Carbon Monoxide Alarm User Manual


 
This alarm monitors the air at the device and is designed to
alarm before CO levels become life threatening. This allows
precious time to leave the house and correct the problem. This is
only possible if the devices are properly located, installed and
maintained as described in this manual.
Gas Detection at Typical Temperature and Humidity Ranges:
This device is not formulated to detect CO levels below 30 ppm
typically. UL tested for false alarm resistance to Methane (500 ppm),
Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm),
Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm).
Values measure gas and vapor concentrations in parts per million.
Audible Alarm: 85dBA minimum at 10 feet (3 meters).
TO RETURN A CO ALARM
Should you experience problems with your CO alarm,
proceed as follows:
1. Turn off electrical power to the CO alarm.
2. Twist the CO alarm counter-clockwise to remove it from its
mounting plate.
3. Unplug the connector from the back of the CO alarm. Do not
remove the wire connection; leave the connector for your
replacement CO alarm.
4. Remove battery from CO alarm. Do not ship CO alarm
with battery still in battery drawer.
5. Carefully pack (the manufacturer cannot be responsible for
consequential damage) and return to the manufacturer. Include
complete details as to exact nature of difficulties being
experienced and date of installation.
6. Return to: Gentex Corporation, 10985 Chicago Drive, Zeeland,
Michigan 49464. Prior to returning, call Gentex at 800-436-8391
or e-mail FP_RMA@gentex.com to obtain a RMA Number from
our return department.
Pg. C-8
LIMITED WARRANTY
Foraperiodof 12monthsfromthedateofpurchase,ora maximumof18monthsfromthedateof manufacture,
Gentexwarrantstoyou,the originalconsumerpurchaser,that yourCOAlarmwill befreefromdefectsin
workmanship,materials,andconstruction undernormaluseandservice. The COsensorhasalimitedwarranty
periodof5years fromdateofinstallation. If adefectinworkmanship, materials,orconstructionshouldcause
yourCOAlarmtobecomeinoperablewithin thewarrantyperiod,GentexwillrepairyourCOAlarmorfurnishyou
withanewor rebuiltreplacementCOAlarmwithoutchargetoyouexceptforpostagerequiredto returntheCO
Alarmtous. YourrepairedorreplacementCOAlarmwillbereturned toyoufreeofchargeanditwillbe covered
underthiswarrantyfor thebalanceofthe warrantyperiod.
Thiswarrantyisvoid ifourinspectionofyourCOAlarmshowsthatthedamageor failurewascausedby
abuse,misuse,abnormalusage, faultyinstallation,impropermaintenance,or repairs otherthanthoseperformed
byus.
ANYWARRANTIESIMPLIEDUNDERANYSTATE LAW,INCLUDINGIMPLIEDWARRANTIESOF
MERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE,APPLYONLYFORTHE
WARRANTYPERIODSPECIFIEDABOVE. PLEASENOTETHATSOMESTATES DONOTALLOW
LIMITATIONS ONHOWLONGANIMPLIEDWARRANTYLASTS,SOTHEABOVEEXCLUSIONMAYNOT
APPLYTOYOU.
GENTEXWILLNOTBELIABLEFORANYLOSS,DAMAGE,INCIDENTALORCONSEQUENTIAL
DAMAGESOFANYKINDARISINGINCONNECTIONWITHTHESALE,USE,ORREPAIROFTHISCO
ALARM. PLEASENOTETHATSOMESTATESDONOTALLOWTHEEXCLUSIONOR
LIMITATION OFINCIDENTALORCONSEQUENTIALDAMAGES.SOTHEABOVEEXCLUSIONMAYNOT
APPLYTOYOU.
Ifadefectin workmanship,materials,orconstruction shouldcauseyourCOAlarmtobecome
inoperablewithinthewarranty period,youmustreturn theCOAlarmtoGentexpostageprepaid. Youmust also
packtheCOAlarmtominimizetherisk of itbeingdamagedintransit. Youmust alsoencloseareturn address.
COAlarmsreturnedforwarrantyserviceshould besentto: Gentex Corporation, 10985ChicagoDrive,Zeeland,
MI 49464.
Ifwereceivea COAlarminadamaged conditionastheresult ofshipping, wewillnotifyyouandyoumust
fileaclaimwith theShipper.
THISLIMITEDWARRANTYGIVESYOUSPECIFICLEGALRIGHTS. YOU MAYALSOHAVEOTHER
RIGHTSWHICHVARYFROMSTATETOSTATE.
GENTEX CORPORATION
10985 CHICAGO DRIVE, ZEELAND, MI 49464
PHONE: 1-800-436-8391
www.gentex.com
550-0498-A
08-01-08
ImportantNotice:
Thesematerialshavebeen prepared byGentexCorporation("Gentex")for informationalpurposesonly,arenecessarily summary, andarenotpurportedtoserveaslegaladvice andshouldnotbe usedassuch. Gentex makesnorep-
resentationsandwarranties,expressor implied,thatthesematerialsarecompleteandaccurate, up-to-date, orincompliancewithallrelevantlocal,stateand federal laws,regulationsandrules. Thematerialsdonotaddressall legal
considerationsasthereis inevitable uncertainty regardinginterpretation oflaws, regulationsandrulesandtheapplicationofsuch laws, regulationsandrulesto particular factpatterns. Eachperson'sactivitiescandifferentlyaffectthe
obligationsthatexistunder applicablelaws,regulationsorrules. Therefore, thesematerialsshouldbeusedonlyforinformationalpurposes andshouldnotbe usedas asubstituteforseeking professionallegaladvice. Gentexwillnot
beresponsibleforany actionorfailureto act inrelianceupontheinformationcontainedinthismaterial.
WARNING! CO alarms are designed to alarm before there is an
immediate life threat. Since CO gas can not be seen or smelled,
never assume it is not present.
An exposure to 100 ppm of CO for 20 minutes may not affect a
healthy adult, after 4 hours of exposure at the same level may
cause headache.
An exposure to 400 ppm of CO may cause headaches in a healthy
adult after 35 minutes and could cause death after 2 hours.
NOTICE: This device measures exposure to CO over time. This
device alarms if CO levels reach a certain minimum over an extend-
ed amount of time. The device will go into alarm before the onset of
symptoms in healthy adults. It is important to have early notification
of a potential hazard, while still having the ability to react in time. In
many reported cases of CO exposure, victims may be aware that
they were not feeling well, but became disoriented and could no
longer react well enough to exit the building or get help.
NOTE: Healthy adults may not experience any symptoms of CO
exposure when the device alarms, however infants, young children,
pregnant women, elderly people, people with cardiac, respiratory or
other health related issues may be more quickly and severely
affected by CO exposure. If you are experiencing even mild
symptoms of CO poisoning, consult a medical professional
immediately.
Standards: Underwriters Laboratories, Inc. Single and Multiple
Station carbon monoxide alarms UL 2034. For your information, the
UL 2034 Standard, reads as follows:
Underwriters Laboratories, Inc UL 2034, Section 1-1.2 Carbon
monoxide alarms covered by these requirements are intended to
respond to the presence of carbon monoxide from sources such as,
but not limited to, exhaust from internal-combustion engines, abnor-
mal operation from fuel-fired appliances and fireplaces. CO alarms
are intended to alarm at carbon monoxide levels below those that
could cause a loss of ability to react to the dangers of carbon
monoxide exposure.