10
10. Attach limit switch wires
.
• Uncoil limit switch wires.
–
Place into channels located along top of rail
.
–
Run wires back to power head through hole in top
of power head (Fig. 1-12)
.
– Use wire clips to hold wires in place (Fig. 1-13).
• Attach limit switch wires to terminals on power
head (Fig. 1-14)
.
–
White wire (“OPEN”) to terminals #4 and #5.
–
Brown wire (“CLOSE”) to terminals #5 and #6.
• Bundle extra wire and lay it on top of power head
(Fig. 1-14 inset).
9. Attach limit switches.
2 switches included, “CLOSE” limit switch (brown
wire) and “OPEN” limit switch (white wire)
(Fig. 1-10).
• Turn set screws (39) into threaded holes, just
enough so screw stays in place. (Fig. 1-10).
• Point arrow on top “CLOSE” limit switch toward
door end of rail.
–
Place “CLOSE” limit switch (Brown wire) on rail
about 12” from rail strap (Fig. 1-11).
–
Gently tighten set screw enough to keep switch
from moving.
• Point arrow on top “OPEN” limit switch toward
door end of rail.
–
Place “OPEN” limit switch (white wire) on rail
where chain attaches to carriage slide. (Near
the power head.)
–
Gently tighten set screw enough to keep switch
from moving.
FIG. 1-10 Identify limit switches / insert set screws.
FIG. 1-11 Place limit switches.
FIG. 1-13 Wire clips.
FIG. 1-12 Run wire to power head.
FIG. 1-14 Attach wire at power head terminals.
[
39
]
[
41
]
Bundle
Wire
hole
4
5
6
#8-32 x 1"