Genie 4024H Garage Door Opener User Manual


 
• With the door closed, pull release handle
DOWN and let go to release door carriage
assembly from drive system.
• Raise door manually approximately 3’- 4’ and
release.
– Door should remain stationary or move very
slightly.
– If door moves quickly, CONTACT A TRAINED
DOOR SYSTEM TECHNICIAN.
• Close the door.
• Verify RED block in carriage is in the up position.
(refer to page 19)
– Operate door using remote or wall console.
– Door will re-attach itself to carriage assembly.
©2010 The Genie Company 12/2010
18
WARNING
Garage door hardware (springs, cables, brackets,
pulleys, etc.) are under extreme pressure and
tension.
DO NOT attempt to repair or adjust door
springs or any hardware, and DO NOT OPERATE
garage door automatically or manually if door
is improperly balanced or springs are broken.
CONTACT A TRAINED DOOR SYSTEM
TECHNICIAN.
ROUTINE MONTHLY MAINTENANCE
Basic monthly maintenance tasks.
Safe-T-Beam® System Check
• Door balance
• Contact reverse
Instructions for these tasks and others are found on
the following pages.
DOOR BALANCE (SPRING TENSION)
3’ - 4’
Sectional Door
3’ - 4’
One-Piece Door
FIG. 6-1 Door balance
WARNING
Use wall console supplied with opener. Other
approved wall consoles may be available.
Unapproved or incompatible wall consoles can
cause the opener to operate unexpectedly.
Safe-T-Beam® (STB) SYSTEM CHECK
• STB Red and Green LEDs ON steady, system OK
• STB Red LED flashes
– Check for obstruction
– Check alignment
– Verify wire routing from
STBs to STB connection in
powerhead
– Check for signal interference
from another Safe-T-Beam®
unit
• No STB Red or Green LED displayed
– Check wiring and wire connections
STB BWC IWC
NOT
USED
NOT
USED
NOT
USED
NOT
USED
FROM STBs
FROM WALL
CONSOLE
FIG. 6-2 2 x 4 under center of door opening
CONTACT REVERSE TEST (Monthly test)
The Force and Limit settings MUST be
COMPLETED before testing. (See pages 6-7)
1. Test.
• Open garage door using wall console.
– Place a 2" x 4" board (laid flat) under center of
garage door opening (Fig. 6-2).
• Close garage door using wall console.
• When door contacts board, the door must
stop (within 2 seconds) and reverse direction
returning to open position.
2. Adjustment.
• If the door:
– Stops before it contacts the 2 x 4 board, it may
simply be responding to an improperly set
down limit. Return to pages 6-7 and repeat
steps 1 through 10 to correct down limit.
– Stops after contacting the 2 x 4 board and
does not reverse, it may need an adjustment
to the down limit. Return to pages 6-7 and
repeat steps 1 through 10 to correct down
limit.
• Test again. Repeat as necessary until door
reverses upon contacting board.