Genie 1042 Garage Door Opener User Manual


 
PN# 36420Supplement, 10/27/2008
16
3.Securely fasten wires.
Securely fasten wires to ceiling and
wall using insulated staples provided.
– Use insulated staples.
– Staples should be snug only.
If rear cover is attached to power head,
remove it.
On power head:
– Route Wall Button wires through wire guide.
– Split and strip ends of wire (Fig. 3-2 on
previous page).
Insert wire into terminal holes and lightly press in
the orange locking clips above each terminal
hole. (You can use a pencil or small screwdriver
to comfortably press in locking clips.) The white
wire into #1 terminal hole and striped wire into
the #2 terminal hole.
Confirm wire lock by lightly tugging on the wire.
The wire should remain in the terminal hole.
Do NOT install rear cover yet.
4. Mounting.
Fasten Wall Button to wall with 2 screws
(provided) (Fig. 3-4).
Remove protective backing from "Entrapment"
warning label (Fig. 3-5). The "Entrapment" label
is located in the center of this manual.
– Stick label on wall near Wall Button.
FIG. 3-4 Mounting Wall Button.
Insulated
Staple
+–
PB
Infared Sensor
123456
FIG. 3-3 Insert wires
.
(Power Head With Rear Cover Removed)
1234
Terminal
Holes
Locking
Clips
56
FIG. 3-5 Mounting Entrapment warning label.