16
To remove an error code: 1. Unplug transformer.
2. Correct defect.
3. Plug transformer in.
4. Wait for at least 6 minutes. The error code will return if the reason for
the error code was not corrected.
NO SOFT
WATER
CONTROL SHOWS
WRONG TIME AND DAY,
AND/OR IS FLASHING.
CONTROL
DISPLAY
BLANK.
CONTROL DISPLAY SHOWS
CORRECT TIME AND DAY
AND IS STEADY.
Check electrical
power to control
(outlet, transformer,
power cable, all
connections).
Do manual
diagnostics.
NO POWER
POWER OK
REPAIR AS
NEEDED
CONTROL
DEFECTIVE
Do manual
diagnostics to
verify proper
function.
Electrical power was off.
Reset the correct time of
day.
Investigate reason for
power loss.
About the water softener system.
Service: Electronic Demand Time Features and Service
If you are not getting soft water, and an error
code is not displayed, use the procedures below
to find the problem. First make the following
visual checks.
VISUAL CHECKS:
1. Is there electrical power to the outlet the
water softening system transformer is
plugged into?
2. Is there sufficient salt in the storage tank?
3. Is the softener bypass valve directing water
for soft water service?
4. Is the valve drain hose open to the drain,
not more than 8′ above the softener, and
unobstructed? If hose is above 8′, see page 7,
section 4.
If you do not find a problem with the visual checks,
continue below.
Service: Timer/Softener, Service Checkout Procedure
ERROR CODE
DISPLAYED ERR 01 ERR 02 ERR 03 ERR 04 ERR 05
POSSIBLE DEFECT • Motor • Position • Motor • Position • Control
inoperative switch inoperative switch or
or wiring wiring
harness harness
• Wiring • Control • Control • Control
harness or
connection
to switch
• Position
switch
• Control