GE SHOWBIZ Indoor Furnishings User Manual


 
GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE
77
GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE
76
Discharge lamps continued
Ballast G53398. T
10A
HBC/MCB
Fuse
PFC
35µF 250V
GC2382
L
N
220/250V
50Hz
Supply
Sw
Biassed Off
R-100
2.5W
C-1µF
250V
HT HT
12kV
Output
Irem
AD312/R
Igniter
200W CID Lamp
Ref 99-0211
Sw - Normally open contacts - Manual switch or 2 second ON timer
Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
123E
SG
200 Watt CIDHot-Restart Lamp Circuit Diagram
Ballast G53371 .T
13A
HBC/MCB
Fuse
PFC
40µF 250V
2xGC2331
L
N
220/250V
50Hz
Supply
C-0.47µF
250V
B
G53444 or
Bag Turgi
SE 15/7U
Igniter
400W CSI
Ref 99-0201
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
Lp
N
R-100
2.5W
9kV
400 Watt CSILamp Circuit Diagram
Ballast G53307. T
20A
HBC/MCB
Fuse
PFC
175µF 250V
7xGC2346
L
N
220/240V
50Hz
Supply
B
G53444 or
Bag Turgi
SE 15/7U
Igniter
1000W CSI Lamp
Ref 99-1222
or 99-0221
Lampholder for 99-1222 - Bender & Wirth 938/223 and for 99-0221 - Bender & Wirth 933/1419
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
Replace G53445 (or Bag Turgi SE600/D) igniter sparkgap element when replacing a failed lamp
Lp
N
9kV
Lamp
1000 Watt CSILamp Circuit Diagram
Ballast Irem ZA57
16A
HBC/MCB
Fuse
PFC
80µF 250V
4xGC2331
L
N
220/240V
50Hz
Supply
C-0.47µF
250V
B
G53444 or
Bag Turgi
SE 15/7U
Igniter
575W CID Lamp
Ref 99-0415
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
Lp
N
R-100
2.5W
9kV
Lampholder
Bender & Wirth
933/1419
575 Watt CIDLamp Circuit Diagram