GE PDW9880J Air Conditioner User Manual


 
10
Receptacles/Sub-bases
RAK204U RAK204D15P RAK204D20P RAK204D30P RAK204E15 RAK204E20 RAK204E30
Voltage N/A 230/208 230/208 230/208 265 265 265
Amps N/A 15 20 30 15 20 30
Receptacle N/A NEMA6-20R NEMA6-20R NEMA6-30R NEMA7-15R NEMA7-20R NEMA7-30R
230/208 Volt sub-bases include appropriate power cord kit.
265 Volt units are to be direct connected. Cordset through enclosed chaseway into interior sub-base receptacle meets the NEC requirements.
Sub-bases
Tandem
230/208V 15 Amp
NEMA6-15R
Perpendicular
230/208V 20 Amp
NEMA6-20R
Large tandem
230/208V 30 Amp
NEMA6-30R
265V 15 Amp
NEMA7-15R
265V 20 Amp
NEMA7-20R;
receptacle used
On 265V sub-base
GE0720-3
265V 30 Amp
NEMA7-30R;
receptacle used
On 265V sub-base
GE073
Power connection kits are required on all Zoneline
®
chassis (see chart below).
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the
building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent
connection kit would be used. 265 volt cord set units must be installed in compliance with National Electrical Code
®
.
Power connection kits
Required on all models.
See specification sheet
for heater KW and branch
circuit ampacity.
RAK3153/3203
230/208 volt line cord
connection kit
RAK4157/4207/4307
230/208 volt universal
power supply kit
RAK5157/5207/5307
265 volt universal power
supply kit
230/208 volt Line cord connected units
LCDI Power Connection Kit RAK3153 RAK3203 RAK3303
Heater KW 2.55/2.09 3.45/2.82 5.00/4.09
Watts 2,550/2,090 3,450/2,820 5,000/4,090
BTUH 8,600/7,100 11,700/9,600 17,000/13,900
Amps 11.6/10.6 15.6/14.2 22.4/20.4
Min. circuit amps 15 20 30
Recommended
protective
device
15 amp
time delay
fuse or breaker
20 amp
time delay
fuse or breaker
30 amp
time delay
fuse or breaker
265 volt Permanent connected units* (Cord set)
RAK5172 RAK5202 RAK5302
2.55 3.45 5.0
2,550 3,450
5,000
8,600
11,700 17,000
10.3 13.8 19.6
15 20 30
15 amp
time delay fuse
20 amp
time delay fuse
30 amp
time delay fuse
*To be used with sub-base
230/208 volt Direct connection kit**
RAK4157 RAK4207 RAK4307
Heater KW 2.55/2.09 3.45/2.82 5.00/4.09
Watts 2,550/2,090 3,450/2,820 5,000/4,090
BTUH 8,600/7,100 11,700/9,600 17,000/13,900
Amps 11.6/10.6 15.6/14.2 22.4/20.4
Min. circuit amps 15 20 30
Recommended
protective
device
15 amp
time delay
fuse or breaker
20 amp
time delay
fuse or breaker
30 amp
time delay
fuse or breaker
**To be used with sub-base or connection to building wiring
265 volt Direct connection kit**
RAK5157 RAK5207 RAK5307
2.55 3.45 5.0
2,550 3,450
5,000
8,600
11,700 17,000
10.3 13.8 19.6
15 20 30
15 amp
time delay fuse
20 amp
time delay fuse
30 amp
time delay fuse
**To be used with sub-base or connection to building wiring