Cable testing
Verify the installation by doing a cable test for each cable run.
Keeping documentation of each test will protect you if a
damaged cable is discovered after the sheetrock has been
installed. Consult the ANSI EIA/TIA-570-B testing section for
the following testing details:
Continuity testing
Near-end crosstalk testing
ANSI EIA/TIA-570-B standard testing
Installer programming
When you power up the room station, it will show a station
disabled message. To get the room station up and running, you
must add the station address. The address cannot be one that is
already used and the room station address must match the audio
zone address.
To access installer programming, press the top two control
buttons on the room station (Music and Intercom) simulta-
neously.
The Setup menu will display with the following menu options,
(turn the selection knob to navigate to an item and press the knob
to select it):
Room station address. Use this option to select a room
station address.
Display settings. Use this option to set the following
settings:
Screen timeout
Backlight timeout
Backlight level on
Backlight level off
LED level on
LED level off
Contrast level
Intercom settings. Use this option to set the following
settings:
Edit station name
Talk timeout
Hand free enabled
Call blocking
Chime volume
Audio settings. Use this option to set the following
settings:
Master mode enabled
Volume limit
Intercom over speakers
Edit source
Door enabled. The door enabled feature has a factory
default of No. Use this option to toggle the feature to Yes if
your installation includes a door strike and this room station
controls the door.
System info. Use this option to view system information
such as hardware and software revision numbers.
Restore defaults. Use this option to restore settings to the
factory defaults.
Exit menu. Use this option to exit the Setup menu.
Refer to the room station user documentation for more program-
ming information.
FCC compliance
This device complies with part 15 of the FCC rules. Operation is subject to the
following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Specifications
Power 100 mA powe supplied by the intercom hub
Operating temperature 0 to 120°F (-17 to 48°C)