GE ASW05 Air Conditioner User Manual


 
Normal Operating Sounds
You may hear a pinging noise caused by
water being picked up and thrown against the
condenser on rainy days or when the humidity
is high. This design feature helps remove
moisture and improve efficiency.
You may hear the thermostat click when the
compressor cycles on and off.
Water will collect in the base pan during
high humidity or on rainy days. The water
may overflow and drip from the outdoor side
of the unit.
The fan may run even when the compressor
does not.
Troubleshooting Tips…
ge.com
Problem Possible Causes What To Do
Air conditioner The air conditioner Make sure the air conditioner plug is pushed
does not start is unplugged. completely into the outlet.
The fuse is blown/circuit Check the house fuse/circuit breaker box and replace
breaker is tripped. the fuse or reset the breaker.
Power failure. If power failure occurs, turn the air conditioner Off.
When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor
overload.
The current interrupter Press the RESET button located on the power cord plug.
device is tripped.
If the RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service technician.
Air conditioner does Airflow is restricted. Make sure there are no curtains, blinds or furniture
not cool as it should blocking the front of the air conditioner.
The temp control may On models with touch pads: In Cool mode, press the
not be set correctly. Decrease pad.
On models with control knobs, turn the temperature
knob to a higher number.
The air filter is dirty. Clean the filter at least every 30 days.
See the Operating Instructions section.
The room may have been hot. When the air conditioner is first turned on, you need
to allow time for the room to cool down.
Cold air is escaping. Check for open furnace registers and cold air returns.
Set the air conditioner’s vent to the closed position.
Cooling coils have iced up. See “Air conditioner freezing up” below.
Air conditioner Ice blocks the air flow On models with control knobs, set the mode control
freezing up and stops the air conditioner at Fan Only and the fan switch to HI
from cooling the room.
On models with touch pads, set the controls at
High Fan or High Cool and set the thermostat to
a higher temperature.
The remote control is The batteries are inserted Check the position of the batteries. They should be
not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. Replace the batteries.
Water drips outside Hot, humid weather. This is normal.
Water drips indoors The air conditioner is not For proper water disposal, make sure the air conditioner
tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture removed from air This is normal for a short period in areas with little
base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
“E1” appears Function error code. Unplug the air conditioner. Wait 3 minutes and plug it
in the display back in.
Timer or Sleep feature A power outage or interruption In the case of a power outage or interruption, the unit
not working properly occurred. Timer and Sleep features will reset to the original setting.
You may need to set a new time if desired.
Consumer SupportTroubleshooting Tips
Operating InstructionsSafety Instructions
Installation Instructions
13