GE AJCQ 06 Air Conditioner User Manual


 
Vent Control
The vent control is located behind the front grille on
the right side of the air discharge area. When set at
CLOSE, only the air inside the room will be circulated
and conditioned. When set at OPEN, some inside air is
exhausted outside.
To open or close the vent:
1. Remove the front grille.
2. Remove the vent card screw.
3. Remove vent card, turn it over and replace it by
locating rear hole in card over locating pin inside air
discharge and reattaching screw at front.
Horizontal louvers
on the front grille let
you control the air
direction up and
down.
Remove the front
grille to adjust the
vertical louvers
side-to-side to
direct the air
left or right.
Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
5
Air Direction
Locating hole
ge.com
COOL MODE
Remote Control
1. Press COOL pad.
2. Press LOW, MED or HI pads to set desired fan speed.
3. Press the INCREASE / DECREASE pads to set the
desired temperature 60°F to 85°F in 1°F increments.
Control Panel
1. Press the MODE pad until the COOL indicator light is
lit and the LOW, MED or HI indicator light is lit for
the desired fan speed.
2. Press the INCREASE / DECREASE pads to set the
desired temperature 60°F to 85°F in 1°F increments.
A thermostat is used to maintain the room
temperature. The compressor will cycle on and off
to keep the room at the set level of comfort. Set the
thermostat at a lower number and the indoor air will
become cooler. Set the thermostat at a higher number
and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on
while set to COOL, it will take approximately 3 minutes for
the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the COOL mode and
HIGH or MED fan with a middle set temperature.
For Maximum Cooling—Select the COOL mode
and HIGH fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the COOL mode
and LOW fan with a middle set temperature.
NOTE: If you switch from a COOL setting to OFF or to
a fan setting, wait at least 3 minutes before switching back
to a COOL setting.
FAN MODE
Use the FAN mode to provide air circulation and
filtering without cooling. Since fan only settings do not
provide cooling, a temperature setting will not be
displayed.
Remote Control
Press FAN pad. Press LOW, MED or HI pads to set
desired fan speed.
Control Panel
Press the MODE pad until the FAN indicator light is lit
and the LOW, MED or HI indicator light is lit for the
desired fan speed.
Fan Switch
The fan switch is located behind the front grille on the
control box. Access through a hole in control box.
When set at CYCLE (down) the fan cycles on and off.
When set at CONT (continuous, up) the fan runs all the
time providing a more balanced temperature. The unit
is shipped in the CONT setting.
Screw hole
OPEN position
(Mesh end toward back)
CLOSE position
(Mesh end toward front)
Locating hole
Screw hole
The unit leaves the factory set at the CLOSE position.