4
Consumer Support
Troubleshooting Tips
Operating Instructions Safety Instructions
Troubleshooting Tips
Care and Cleaning Safety InstructionsOperating Instructions
Bucket full light
indicates bucket
needs to be
emptied
About the controls on the dehumidifier.
Controls
Power Pad
Press to turn the dehumidifier on and off.
Continuous
Select for the dehumidifier to
operate continuously at its maximum
dehumidification settings until the bucket is
full. The Humidity Set Control Pads cannot
be used when Continuous is on.
Humidity Set Control Pads
The humidity level can be set within a range
of 35% RH (Relative Humidity) to 80% RH
(Relative Humidity) in 5% increments.
For drier air, press the pad and set to
a lower percent value (%).
For damper air, press the pad and set
to a higher percent value (%).
When you first use the dehumidifier, set
the humidity control to 45% or 50%. Allow
at least 24 hours for the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a lower setting or select Continuous
for maximum dehumidification.
Fan Speed Pads
Control the fan speed.
Press to select either High or Normal fan
speed.
Set the fan control to High for maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Normal.
Display
Shows the set % humidity level while
setting, then shows the actual (+/– 5%
accuracy) room % humidity level.
Error Codes
E1 – Humidity sensor error – Unplug the
unit and plug it back in.
E2 – Temperature sensor error – Unplug
the unit and plug it back in.
P1 – Unit is defrosting – Allow the unit time
to automatically defrost. The error will
clear after the unit self defrosts.
P2 – Water bucket is full – Empty the water
bucket and replace. See the Removing
Collected Water section.
▲
▼
Other Features
BUCKET FULL Light
Glows when the bucket is ready to be emptied,
or when the bucket is removed or not replaced
in the proper position.
Auto Shut Off
The Water Level Control Switch shuts off the
dehumidifier when the bucket is full, or when
the bucket is removed or not replaced in the
proper position.
Auto Defrost
When frost builds up on the evaporator coils,
the compressor will cycle off and the fan will
continue to run until the frost disappears.
Power Outage
In the case of a power outage or interruption,
the unit will automatically re-start, in the settings
last used, after the power is restored.
High fan
indicator light
Normal fan
indicator light
Power on
indicator light
Continuous
operation on
indicator light