GE AER05 Air Conditioner User Manual


 
Installation Instructions
WINDOW REQUIREMENTS
These instructions are for a standard
double-hung window. You will need to
modify them for other types of windows.
The air conditioner can be installed
without the accordion panels if needed
to fit in a narrow window. See the
window opening dimensions.
All supporting parts must be secured
to firm wood, masonry or metal.
The electrical outlet must be within
reach of the power cord.
1
12 min.
24-1/2 to 34-1/4
(With accordion panels)
17 min.
(Without accordion panels)
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the
air conditioner to tilt toward the outside,
and will keep it from draining properly.
To adjust for this, attach a piece of wood
to the stool.
WOOD PIECES–
WIDTH: 2
LENGTH: Long enough to fit inside the
window frame.
THICKNESS: To determine the thickness,
place a piece of wood on the stool to
make it 1/2 higher than the top of the
storm window frame.
Attach securely with nails or screws
provided by the installer.
1/2higher
than frame
Storm
window
frame
Wood
Stool
2
8
PREPARE THE AIR CONDITIONER
Install the top mounting rail with 2 Type A
screws from the outside of the case.
Slide the left and right accordion panels
into the top and bottom mounting rails.
Attach the accordion panels to the case
using 2 Type A screws on each side.
3
A
B
C
Top mounting rail
Bottom mounting rail
Type A
screws
Top mounting rail
Bottom mounting rail
Accordion
panel
BACK