Installation Instructions
19
OPTIONAL—DRAIN KIT INSTALLATION
Dry Air 25 Series models are designed to improve dehumidification by 25%. Since more moisture will be removed from
the air, there is a greater possibility that water will drip from the wall case than with a standard unit. To prevent this
water from dripping onto external building walls, we recommend the use of RAD10 Drain Kit.
External Drain
See the Installation Instructions
in the RAD10 kit.
Internal Drain
See the Installation Instructions in
the RAD10 kit.
Type“A”screw formetal caseor
Type“B”screw formoldedcase
Squaredrain holes
Squaredrain holes
(The drainislocated
underthe cabinet)
Neoprenesponge gasket
Steelmountingplate
1/2″O.D.drain tube
Neoprenesponge gasket
Steelmountingplate
Type“A”screw formetal caseor
Type“B”screw formoldedcase
Alternate:
6″long,1/2″O.D. straight
coppertube