GE 23-11-2129N-002 Air Conditioner User Manual


 
Customer ServiceTroubleshooting Tips
Operating Instructions
Safety Instructions
Installation Instructions
Read completely, then follow step-by-step.
Window Requirements
These instructions are for a standard double-
hung window. You will need to modify them for
other types of windows.
The air conditioner can be installed without the
filler panels if needed to fit in a narrow window.
See the window opening dimensions to the right.
All supporting parts must be secured to firm
wood, masonry or metal.
The electrical outlet must be within reach of the
power cord.
Window opening dimensions are for a
standard double-hung window.
18
5
8
min.
30
3
4
to 46
1
2
(with filler panels)
26
3
4
min.
(without filler panels)
Storm Window Requirements
A storm window frame will not allow the air
conditioner to tilt towards the outside and will keep
it from draining properly. To adjust for this, attach a
piece of wood to the stool.
WOOD PIECES—
WIDTH:
2
LENGTH:
Long enough to fit inside the window
frame.
THICKNESS:
To determine the thickness, place a
piece of wood on the stool to make it 1/2higher
than the top of the storm window frame.
Attach securely with nails or screws provided by
the installer.
1/2higher
than frame
Storm window
frame
Wood
Stool
1
2
9