GE 106585 Vacuum Cleaner User Manual


 
11
6. Place new belt around motor shaft.
..
..
.
Left side view
7. Place belt around brush roll pulley.
8. Pull right side of brush roll to stretch belt. Secure
right end cap into base.
9. Align left end cap with square in base. Push end
cap into place; see left side view.
10. Rotate brush roll to seat belt.
11. Replace the hood. Make sure hood front is behind
furniture guard.
12. Tighten screws.
Use GE brand replacement belt, Style GE-1,
Part No. 106615.
5
6
7
8
9
To Change Dust Cup Foam Filter:
NOTE: Turn off the switch and unplug the electrical
cord before changing the Foam Filter. Never
operate the vacuum cleaner without the dust cup
or the foam filter assembly.
Release dust cup by rotating dust cup latch to the left
pointing to the unlock symbol ( ). Pivot dust cup out
and away from cleaner and remove.
Remove cyclonic dust cup by pulling latch (1) forward,
pivoting cyclonic dust cup out and lifting up. To replace
cyclonic dust cup, put bottom of cyclonic dust cup in
place by aligning tabs in slots and pivot top assembly
back into place. Push down on latch (1), making certain
that latch securely snaps and overlaps tabs at top of dust
cup.
To maintain good performance, check and clean the Foam
Filter each time the dust cup is emptied and clean if needed.
The filter can be cleaned by washing with mild detergent
and warm water. Be sure foam filter is completely dry before
reinstalling.
Dust Cup
Latch
Dust Cup
1
2