GE 106575 Vacuum Cleaner User Manual


 
How to Check and Clear Hose Blockages
Low suction or poor pickup may be due to a blockage in the vacuum cleaner.
1. Remove hose from hose retainer and check suction at
end of hose - if little or no suction, check disposable
dust bag. Change if needed. If no improvement proceed
to step 2.
CAUTION: Turn off the switch and unplug the electrical
cord before clearing hose.
2. Remove electrical cord from cord hooks. Disconnect
the clear tube by turning quarter turn fastener to the
right to release, then lift away from cleaner.
Check for any obstructions that may be in the tube.
Any obstructions can be removed by using a blunt
instrument to clear the tube.
3. To completely release hose from the unit, remove two
screws.
Any obstructions can be removed by using a blunt
instrument to clear the hose. Flexing the hose may help
loosen the blockage.
After clearing blockage, reverse above steps to reassemble
unit.
2. Disconnect Clear Tube.
1. Remove hose from hose retainer and
check suction at end of hose.
3. Release hose from unit.
1
10
Hose
Retainer
Clear
Tube
2
Quarter
Turn
Fastener
3
Two Screws
Electrical
Cord