6
· Multi-stage centrifugal pump, SS construction (SS end castings and wetted parts,
Noryl* internals) on the 3 to 3 to 34m
3
/hr and AS (all Stainless Steel components)
on the 45m
3
/hr.
· Electrical package includes Programmable Logic Controller (PLC), IEC66 control
enclosure with a 24VDC control circuit, Siemens TP070 operator interface terminal,
and a Siemens S7-200 PLC.
· Twenty (20)-inch, 30-inch, or 40-in SS pre-filter housing, including 5-micron car-
tridge filters, GS05-20-XK, GX05-30-XK, GX05-40-XK for the E8-CE and 20-inch
PVC pre-filter housings, including 5-micron cartridge filters for the E4H-CE.
· Pre-filter, post-filter, primary, pump discharge, and final pressure gauges.
· Concentrate and permeate flow meters.
· Digital conductivity monitor, panel-mounted, for permeate quality monitoring with
high conductivity alarm.
· Gauges, valves, and rigid plumbing of SS or plastic.
·
Stainless Steel concentrate and recycle valves.
· External control capabilities (level control, pretreatment lockout).
· ALARMS included: low inlet pressure, high permeate pressure, high conductivity,
high pH, starter overload trip, and high temperature.
· Permeate purge capability.
·
High permeate pressure shutdown.
·
Low inlet pressure shutdown.