Stovax (P)8136**UC Indoor Fireplace User Manual


 
MODEL GAS GAS INLET AERATION INJECTION BURNER INPUT GAS FLOW RATE
TYPE CATEGORY PRESSURE SIZE SIZE
PRESSURE(mb)(pre-set)
(kW) (m3/hr)
(mb) HIGH LOW HIGH LOW HIGH LOW
NATURAL G20 20 mb 7.5mm 1100 9.0 2.6 12 6 1.11 0.56
TAHOE BUTANE G30 29 mb 3 * 15mm 400 16.3 4.6 12 6 0.34 0.17
PROPANE G31 37 mb 3 * 15mm 400 21.1 6.0 12 6 0.43 0.22
SMALL NATURAL G20 20 mb 7.5 mm 1600 5.4 1.7 13 6.5 1.21 0.61
ASPEN & BUTANE G30 29 mb 3 * 15mm 400 20.0 5.6 13 6.5 0.36 0.18
CHAMONIX PROPANE G31 37 mb 3 * 15mm 400 25.3 7.0 13 6.5 0.48 0.24
NATURAL G20 20 mb 7.5mm 1600 8.3 2.6 16 8 1.51 0.76
BUTANE G30 29 mb 3 *15mm 600 15.7 4.3 16 8 0.45 0.23
PROPANE G31 37 mb 3 * 15mm 600 20.5 5.6 16 8 0.58 0.29
12
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
MEDIUM
& LARGE
CHAMONIX
& LARGE
ASPEN