Stovax P8050 Indoor Fireplace User Manual


 
5
4.2 • Holdinthecontrolknobandrotateanti-clockwiseuntil
the knob is pointing at the ignition symbol ( )
• Applyalightedmatchtothepilothood,Diagram3
3
AR0897
4.3 When the pilot is lit:
• Extinguishthematchandcontinuetoholdintheknob
for 5 to 10 seconds
4.4 • Closethedoorandtightentheboltandnutwitha
spanner
4.5 The fire can now be operated as previously described.
5. CLEANING THE STOVE
WARNING: DO NOT ATTEMPT TO CLEAN THE STOVE UNTIL
IN A COLD CONDITION. THE STOVE RETAINS ITS HEAT FOR
A CONSIDERABLE TIME AFTER SHUTDOWN.
ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS
The fuel effect and side panels in this appliance are made
from Refractory Ceramic Fibre (RCF), a material which is
commonly used for this application.
Protective clothing is not required when handling these
articles, but we recommend you follow normal hygiene
rules of not smoking, eating or drinking in the work area
and always wash your hands before eating or drinking.
To ensure that the release of RCF fibres are kept to a
minimum, during installation and servicing a HEPA filtered
vacuum is recommended to remove any dust accumulated
in and around the appliance before and after working on it.
When servicing the appliance it is recommended that the
replaced items are not broken up, but are sealed within
heavy duty polythene bags and labelled as RCF waste.
RCF waste is classed as stable, non-reactive hazardous waste
and may be disposed of at a licensed landfill site.
Excessive exposure to these materials may cause temporary
irritation to eyes, skin and respiratory tract; wash hands
thoroughly after handling the material.
5.1 • Releasethedoorasdescribedinsection4.1
5.2 • Removetheceramiccoals,rearpanel,fuelbedand
burner cover gasket
• Handlethesecomponentswithcareastheyarefragile
5.3 The ceramic coals and fuel bed can be cleaned using a
vacuum cleaner with a soft brush attachment. It is advisable
not to clean the cover gasket as this is very fragile.Ensure all
debris is removed from the burner ports.
5.4 • Replacetheceramics,referringtosection6.
6. FUEL BED ARRANGEMENT
6.1 • Placethewhiteceramiccovergasketontotheburner
• Ensuretheholesalignwiththeburnerports,Diagram4.
4
AR0898
6.2 • Placethefuelbedovertheburner,tallestparttowards
the rear of the firebox, Diagram 5
AR0899
5
6.3 • Carefullyfeedtherearpanelintothefireboxandengage
it between the two locating brackets
• Slidethepaneldownbehindthefuelbed,Diagram6
USER INSTRUCTIONS