6
USER INSTRUCTIONS
3.4 For advice on suitable solid fuels:*
•Contactyourlocalapprovedcoalmerchant
A number of factors can affect the performance of the appliance.
See Section 16 for details.
4. LIGHTING THE FIRE
4.1 For best results:
•Setaircontrols,SeeDiagram5
PR8024
Slide to the far right - resistance will be felt
Wood
Multi-fuel
•Placefirelightersorpaperanddrykindlingwoodonthe
grate
•Lightthepaperorfirelighters,SeeDiagram6
•Leavethedoorslightlyopenasthefireestablishesand
the glass warms to avoid the build-up of condensation
•Addlargerpiecesofwood
Too many logs may smother the fire.
Do not load fuel above the log guard and the secondary
combustion inlets at the back of the firebox.
See Diagram 7
Air Inlets
Log Guard
PR8028
•Closethedoor
Do not leave the door open as this could over-fire and
damage the appliance.
5. RUNNING THE APPLIANCE
5.1 Wood Stove:
The Wood burning setting is:
Maxmium - Right
Minimum - Left
Once the fire is established:
•Movethecontrollevertothecentre
A de-dent ball will locate the arm in the correct position see
Diagram 8.
This position is at maximum for burning wood.
The arm can be moved to the left to control the fire.
Air Wash: Adjust
PR8032
PR8025
•Woodburnsbestonabedofash
•Raketheembersevenlyoverthefirebedandopenthe
Airwash control fully for a few minutes before re-fuelling
5.2 Burn new logs at high output for a few minutes before
adjusting the Airwash control.
• Refuellittleandoftenforclean,efficientburning.