Stovax Logic Hotbox & Convector Fire Indoor Fireplace User Manual


 
11
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
2.4 Ensure that no naked flame or incandescent part of the fire
bed projects beyond the vertical plane of the fireplace
opening.
2.5 The appliance must not be installed in any room that
contains a bath or shower.
2.6 Ensure clearances to combustible materials - see diagram 3
3.1 Before installation, ensure that the local distribution
conditions (identifaction of gas and pressure) and
the adjustment of the appliance are compatible.
3.2 Ensure that the gas supply is capable of delivering the
required amount of gas, and is in accordance with the rules
in force.
3.3 This appliance is supplied complete with a factory fitted
isolation device incorporated into the inlet connection, no
further isolation device is therefore required.
It is important to ensure that any national ventilation
requirements are taken into account during the
installation of this appliance.
4.1 This appliance has a norminal input not exceeding 7.0kw
and therefore does not normally require ant additional
permanent ventilation.
If, however, spillage is detected when commissioning the
appliance, there may be insufficient natural ventilation and
additional ventilation may be required.
For ventilation requirements im thr Republic of Ireland, it
will be necessary to refer to the relavant rules in force.
AIR VENTS MUST NOT BE RESTRICTED.
3
3. GAS SUPPLY
4. VENTILATION
2
215