Stovax 8699 IR Indoor Fireplace User Manual


 
2
Covering the following frames:
Fusion: Model number 8699 GP/IR
1
AR2170
height measured to
the centre top of
bracket = 993mm
centre point
993mm
2.2 To fix the wall bracket:
• Securethebracketintoplacewiththescrewssupplied
• Liftandhooktheframeontothebracket,Diagram2
• Centretheframe
2
AR21668
wall bracket
3. SECURING FUSION FRAME TO THE FIRE
3.1 Access to the controls is behind the drop down lower cover.
There are two fixing brackets either side of the controls:
• Secureframetothefireboxatthebasewithscrews
 suppliedtoensurerigidfixing,Diagram3
3
AR2169
USER INSTRUCTIONS
1. CONTROLS ACCESS
To access the fire's controls with a Fusion Frame fitted:
•Useoneofthedecorativeaerationholestopullforward
the control cover at the foot of the frame
Detailsofthecontrols(andReplacing the Batteries,ifapplicable)
are given in the User section of the fire’s Instruction manual.
2. CLEANING THE FRAME
Only clean the frame when it is cold.
The painted frame of the Fusion should be cleaned using a
damp cloth and buffed with a lint free duster.
INSTALLATION
INSTRUCTIONS
Covering Models 8699GP and 8699 IR
1. GENERAL
1.1 Theseinstructionsaresupplementalto,andmustbereadin
conjunctionwith,theInstallation Instructions (PR0741 for
E-Studio & Logic E-Box Conventional Flue and the
Balanced Flue version in PR0776) supplied with the fire.
1.2 Fitting of the Fusion frame must be carried out after the
appliance has been fully installed and commissioning
tests completed.
2. PREPARATION OF WALL FIXING FOR
FUSION
The Fusion hooks onto a wall bracket (supplied).
• Centrethewallbracketabovethefireandatthe
distancefromthehearth,orbaseofappliance(ifwall
mounted),showninDiagram1
2.1 For the Fusion:
• Findthefire'scentrepointacrossitswidthandmark
• Mark1023mmfromthehearth,orbaseofappliance(if
wallmounted),toestablishthecorrectheight
Fusion