Stovax 7125F Stove User Manual


 
2
1. GENERAL
1.1 These instructions apply to Stockton 3/4/5/6/7 when fitted
with a Smoke Control kit.
NOTE: These appliances have been independently tested to
PD6434 and approved by DEFRA as an exempted appliance
allowing it to burn wood in Smoke Control areas when fitted
with a Smoke Control kit.
Product
Code
Appliance Smoke control kit
Part No.
7125 Stockton Inset Convector ST5SCKIT
1.2 To meet the Smoke Control requirement this appliance must
be operated correctly in order to minimise the amount of
smoke produced.
1.3 Burn only dry wood
1.4 These instructions must be left with the user and kept with
the original instructions they superseded.
2. RECOMMENDED FUELS
2.1 Wood Logs:
•Burnonlyseasonedtimberwithamoisturecontentofless
than 20%
Appliance Maximum Length Maximum Diameter
Stockton Inset
Convector
325mm 100mm
•Drycutwoodfor12to18monthsbeforeuse
Poor quality timber:
Causes low combustion efficiency
Produces harmful condensation
Reduces effectiveness of the airwash and life of the
appliance
Do not burn construction timber, painted, impregnated /
treated wood, manufactured board products or pallet
wood.
3. LIGHTING THE APPLIANCE
3.1 For best results:
•Setaircontrols,Seebelow.
Air Wash: Fully Open
Primary Air: 25% Open
Stockton 7
Stockton8
Stockton 7
Stockton8
Secondary Air:
Fully Open
•Placefirelightersorpaperanddrykindlingwoodonthe
grate
•Lightthepaperorfirelighters,SeeDiagram2
•Leavethedoorslightlyopenasthefireestablishesand
the glass warms to avoid the build-up of condensation
•Addlargerpiecesofwood
Too many logs may smother the fire.
Do not load fuel above the log guard and the secondary
combustion inlets at the back of the firebox.
See Diagram 3