5
USER INSTRUCTIONS
Airwash
Closed Open
Primary Air
Open Closed
Secondary
Combustion
Control (not 1A)
Closed
Open
PR7225a
DOOR HANDLE
1.12 Use a protective gloved hand to operate.
See Diagram 4
DO NOT OPEN THE DOOR WITH BARE HANDS
Door Tool:
Lift and Pull
forward to open
WARNING
Properly installed, operated and maintained this
appliance will not emit fumes into the room.
Occasional fumes from de-ashing and refuelling may occur.
Persistent fume emission is potentially dangerous and
must not be tolerated.
If fume emission does persist:
•Opendoorsandwindowstoventilatetheroom
•Allowfiretoburnoutorsafelydisposeoffuelfromthe
appliance
•Checkforchimneyblockageandcleanifrequired
•Donotattempttorelightuntilthecauseoftheemission
has been identified and corrected
If necessary seek expert advice.
•All open flued appliances can be affected by temporary
atmospheric conditions which may allow fumes to enter
the house. Because of this it is recommended that an
electronic carbon monoxide detector conforming to
BSEN50291 be fitted and maintained.
2. USING THE APPLIANCE FOR THE FIRST
TIME
2.1 To allow the appliance to settle and fixing glues and paint
to fully cure:
•Operatetheapplianceatalowoutputforfirstfewdays
2.2 Do not touch the paint during the first period of use.
2.3 During this time the appliance may give off some
unpleasant odours:
•Keeptheroomwellventilatedtoavoidabuild-upof
fumes.
3. RECOMMENDED FUELS
3.1 Wood Logs:
•Burnonlyseasonedtimberwithamoisturecontentofless
than 20%
Wood Length
Appliance Wood Length
Brunel 1A 250mmm
Brunel 2CB 330mm
Brunel 3CB 400mm
•Drycutwoodfor12to18monthsbeforeuse
Poor quality timber:
— Causes low combustion efficiency
— Produces harmful condensation
— Reduces effectiveness of the airwash and life of the
appliance
Do not burn construction timber, painted, impregnated
/ treated wood, manufactured board products or pallet
wood.