Gardena WP 1800 Water Pump User Manual


 
11
GB
10
GB
4. Storing your Garden Spring Pump
1. Before the frosty season begins, take the pump out of the pond
and clean it.
2. To avoid difficulties when starting up in the spring, we recom-
mend storing the pump in a frost-free location in a container
filled with water. The mains plug must not be submerged.
The product must not be added to normal household waste.
It must be disposed of properly.
5. Cleaning
Cleaning the pump: 1. Remove the filter housing
3
from the motor housing
6
, and
clean it.
2. Turn the pump inlet
5
anticlockwise and pull it vertically off the
motor housing
6
(bayonet socket).
3. Take the impeller
8
out of the motor housing
6
and clean it.
4. Push the cleaned impeller
8
back into the motor housing
6
.
5. Push the pump inlet
5
vertically on to the motor housing
6
and tighten it clockwise. (If the pump is to suck from under-
neath, the thread must face downwards).
6. Push the filter housing
3
back on to the motor housing
6
.
6. Trouble-shooting
Fault Possible cause Remedy
The pump delivers no water Mains plug not plugged in. v Plug in mains plug.
Impeller unit is blocked. v Clean pump.
Impeller running in the wrong v Disconnect from the mains
direction due to insufficient water. and top up with water.
Pump installed out of water v Fill the inlet hose with water.
and not filled.
Filter housing dirty. v Clean filter housing.
The pump delivers a reduced
water flow
CAUTION! Electric shock!
Risk of injury due to mains electricity.
v Before fault-finding, unplug the pump at the
mains.
3
5
8
6
CAUTION! Electric shock !
Risk of injury due to mains electricity.
v Before cleaning the pump, unplug the it from
the mains.
Disposal:
(in accordance with
RL2002/96/EC)
The pump should be stored out of the reach of children.
Storage:
CAUTION!
If any other faults arise, please contact GARDENA Service.
7. Accessories
GARDENA Underwater lights Illumination of garden springs or objects art. 7952
UL 20 / UL 20 S Set in / on the pond. art. 7958
Start water features and lighting from
the terrace or your living room. art. 7874
8. Technical Data
WP 600 (art. 7630) WP 1200 (art. 7631) WP 1800 (art. 7632)
Mains voltage/mains frequency 230 V AC / 50 Hz 230 V AC / 50 Hz 230 V AC / 50 Hz
Rated power 8 W 16 W 30 W
Power cable 10 m; H05-RN-F 10 m; H05-RN-F 10 m; H05-RN-F
Flow 600 l/h 1200 l/h 1800 l/h
Max. delivery head 1,2 m 1,6 m 2,0 m
Max. submersion depth 1 m1 m1 m
Pump connection G 1/2 G 1/2 G 1/2
Media temperature 4 °C – 35 °C 4 °C – 35 °C 4 °C – 35 °C
9. Service / Guarantee
GARDENA guarantees this product for 3 years (from date of
purchase). This guarantee covers all serious defects of the unit
that can be proved to be material or manufacturing faults.
Under warranty we will either replace the unit or repair it free of
charge if the following conditions apply:
The unit must have been handled properly and in keeping with
the requirements of the User’s Manual.
• Neither the purchaser or a non-authorised third party have
attempted to repair the unit.
The feed impeller is a wearing part and is not covered by the
warranty.
This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer/ seller.
If you have any problems with your Fountain Pump Set,
please contact our Service or return the defective unit together
with a short description of the problem – in case of guarantee,
with a copy of the receipt – postage paid to one of the
GARDENA Service Centres listed on the back of this leaflet.
Guarantee
GARDENA radio control set
Work on the electrical parts must only be carried out by
GARDENA Service Centres.