19
GB
If the pump is installed out of water, the filter housing
4
must
be taken off.
1. Pull off the filter housing
4
.
2. Turn the pump inlet
5
anticlockwise and pull it vertically off
the motor housing
6
(bayonet socket).
3. Depending on the pumping application, the pump inlet can be
rotated in 90° steps. Twist the pump inlet
5
accordingly, again
press it vertically on to motor housing
6
and tighten it clock-
wise (see 5. Cleaning).
4. Screw stepped nipples
7
on to the pump inlet
5
and pump
outlet
8
.
5. Connect the pump inlet
5
to the water reservoir with a hose
(1/2
"
or 3/4
"
). The level in the water reservoir must be
higher than the pump inlet
5
.
6. Connect the pump outlet
8
to the spring /gargoyle with a hose
(1/2
"
or 3/4
"
).
7. Fill the hose to the pump inlet
5
with water.
8. Insert the pump plug into a mains socket.
Caution:The pump will start immediately.
9. Use the flow control
3
to set the desired water flow for the
spring.
Commissioning the pump if
it is installed out of water:
5
3
4
6
7
8