Frost-free storage
16
GB
Problem Probable cause Remedy
Pump doesn’t start or Thermal overload switch has v Disconnect plug and clean
suddenly stops during switched the pump off due feed impeller (see 5. Clean-
operation. to overheating. ing).
Observe max. media temper-
ature of 35°C.
No power. v Check fuses and electric
connections.
Dirt particles are jammed v Disconnect plug and clean
in the suction base. suction base (see 5. Clean-
ing).
Pump runs, but output Suction base is clogged. v Disconnect plug and clean
suddenly decreases. suction base (see 5. Clean-
ing).
Attention!
Repairs on electrical parts should only be done by our
GARDENA Service Centres.
If you have any problems with your Pump, please contact our Service.
7. Storage
Store the pump away from frost before the first frost sets in.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
8. Technical Data
Type 6500 SP 8000 SP 13000 SP
(Art. 1792) (Art. 1794) (Art. 1796)
Rated power 250 W 380 W 680 W
Max. delivery capacity 6,500 l/h 8,000 l/h 13,000 l/h
Max. pressure 0.5 bar 0.5 bar 0.9 bar
Max. delivery height 5 m5 m9 m
Max. submersion depth 9 m9 m9 m
Residual water height 30 mm 35 mm 35 mm
Contaminated water
with particle size of max. Ø 25 mm Ø 30 mm Ø 30 mm
Power cable 10 m H05 RNF 10 m H05 RNF 10 m H07 RNF
Pump connection 38 mm (11/2”) / 25 mm (1”) graduated nipple,
option GARDENA Water hose Plug-in-system
Min. water level for operation 80 mm 100 mm 100 mm
Weight approx. 4.3 kg 5.4 kg 7.0 kg
Max. media temperature 35°C 35 °C 35°C
Disposal:
(in accordance with
RL2002/96/EC)