GARDENA Rain Water Tank Pump
4000/2 / 4000/2 automatic
Translation of the original German operating instructions.
Please read the operating instructions carefully and observe the
notes given. Use these operating instructions to familiarise your-
self with the product, the proper use and the safety instructions.
For safety reasons, children and young people under the age
of 16, as well as people not familiar with these operating
instructions, may not use this product. Persons with reduced
physical or mental abilities may use the product only if they are
supervised or instructed by a responsible person.
v Keep these operating instructions in a safe place.
Contents: 1. Area of application of your GARDENA
Rain Water Tank Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3. Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5. Putting into Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
6. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7. Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
8. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
9. Service / Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
1. Area of application of your GARDENA Rain Water Tank Pump
Purpose: The GARDENA Rain Water Tank Pump is particularly suited for
retrieving rainwater from rain water tanks, e. g. the GARDENA
RainWater Tank, and for watering with a sprinkler.
The pump is completely submersible (watertight encapsulation)
and is submerged in the water (to a max. depth of 7m).
Please note:
The pump should not be used for the delivery of salt water,
muddy water, corrosive, easily inflammable or explosive
liquids (e. g. petrol, paraffin, thinners), oil, heating oil or food-
stuffs.
The water temperature should not exceed 35 °C.
2. Safety Instructions
Electrical Safety
In accordance with VDE 0100, the pump
may only be operated in non-accessible
containers and only via a fault current circuit
breaker with a rated leakage current ≤ 30 mA
(DIN VDE 0100-702 and 0100-738,
AS/NZS 3000).
v Please consult a specialised electrical dealer.
Mains power cables should not have a smaller
cross-section than a rubber-sheathed cable of
the designation H05 RNF.
The cable length must be min. 10m.
Only use extension cables authorised in
accordance with HD 516.
Mains plug and extension connections must be
protected from water splashes.