ADJUSTING THE DIRECTION OF AIR CIRCULATION
● Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Control Unit.
● Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow-direction louvers have
stopped moving.
R
DANGER!
● Never place fingers or foreign objects in-
side the outlet ports, since the internal fan
operates at high speed and could cause
personal injury.
● Always use the Remote Control Unit’s
SET button to adjust the vertical airflow
louvers. Attempting to move them
manually could result in improper op-
eration; in this case, stop operation and
restart. The louvers should begin to
operate properly again.
● During use of the Cooling and Dry
modes, do not set the Air Flow Direc-
tion Louvers in the Heating range (4 -
7) for long periods of time, since wa-
ter vapor may condense near the out-
let louvers and drops of water may drip
from the air conditioner. During the
Cooling and Dry modes, if the Air Flow
Direction Louvers are left in the heat-
ing range for more than 30 minutes,
they will automatically return to posi-
tion
3.
● When used in a room with infants, chil-
dren, elderly or sick persons, the air
direction and room temperature
should be considered carefully when
making settings.
Vertical Air Direction Adjustment
Press the SET button (Vertical) (Fig. 6 b9).
Each time the button is pressed, the air direction range will change as follows:
1
2 3 4 5 6 7
Types of Air flow Direction Setting:
For better heating/cooling effect, it is recommended to set the air direction in the
following range.
1,2,3 : During Cooling/Dry modes
4,5,6,7: During Heating mode
The Remote Control Unit’s display does
not change.
● Use the air direction adjustments within the ranges shown above.
● The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Horizontal flow 1
During Heating mode : Downward flow 6
● During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 1; the air direction cannot be adjusted during this pe-
riod.
The air flow direction setting will temporarily become 1 when the temperature of
the air flow is low at the start of the Heating mode.
Horizontal Air Direction Adjustment
Press the SET button (Horizontal)(Fig. 6 b10).
● Each time the button is pressed, the air direction range will change as follows:
1
2
3
The remote control unit’s