3-1. FUNCTION SETTING
Follow the instructions in the Local Setup Procedure, which is supplied with the remote control,
in accordance with the installed condition.
After the power is turned on, perform the Function Setting on the remote control.
The settings may be selected between the following two: Function Number or Setting Value.
Settings will not be changed if invalid numbers or setting values are selected.
3-1-1 INDOOR UNIT
( Factory setting)
Setting Description
Function Number Setting Value
Standard (400 hours)
Long interval (1000 hours)
Short interval ( 200 hours)
No indication
11
00
01
02
03
1-1. Setting the Filter Sign
The indoor unit has a sign to inform the user that it is time to clean the filter.
Select the time setting for the filter sign display interval in the table
below according to the amount of dust or debris in the room.
If you do not wish the filter sign to be displayed, select the setting value for "No indication".
( Factory setting)
Setting Description
Function Number Setting Value
Standard
Slightly lower control
Lower control
Warmer control
30
00
01
02
03
1-2. Cooling Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be selected as shown in the table below.
( Factory setting)
Setting Description
Function Number Setting Value
Standard
Lower control
Slightly warmer control
Warmer control
31
00
01
02
03
1-3. Heating Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.