Fujitsu AIR CONDITIONER Air Conditioner User Manual


 
En-16
WEEKLY TIMER OPERATION
The “OFF Timer” at which the operation will be stopped and the “ON Timer” at which the operation will be started can be combined,
and up to 4 reservations (program
) can be applied for one day, and 28 reservations for a week.
Before creating the program, please adjust the week and time rst, and than send it to the air conditioner.
If the week and time are not adjusted, the program will not be operated at the set time.
Please refer to [Set the day of the week and current time] (page 6).
CAUTION
Operations other than the temperature setting will be the same at the last time operation was stopped,
so Cooling Heating Cooling Heating type of operations cannot be automatically set.
If you set the ON Timer and OFF Timer on the same and for the same time, the air conditioner will run
the ON Timer. If two ON Timers are set at the same time, the air-conditioning will run the program that
was set earlier.
If there is a power interrupting, such as due to a power outage during the WEEKLY timer setting or a
circuit breaker cutting out, the internal timer of the air-conditioning will be incorrect. (See “AUTO Restart”
on page 23.) In such a case, the main timer lamp will notify you of this by ashing, so carry out matching
of the time and date. (See “Set the day of the week and current time” on page 6.)
You cannot use the ON/OFF together with the SLEEP timer.
If you want to run the product on WEEKLY TIMER after the time is up after using the ON/OFF Timer,
Program Timer, or SLEEP Timer within the WEEKLY TIMER, you need to set the WEEKLY TIMER again.
(See page 19.)
Using in these cases of WEEKLY timer
Example of how to set the timer 2
You can specify a given temperature in the ON setting in WEEKLY TIMER.
* You can set the temperature for Auto, Cool, and Dry within the range 64–88 °F, for Heat the range is 50 or 60–88°F.
Even if you set 50, 60, or 62 °F, if you run the product on Auto, Cool, or Dry it will run at 64 °F.
During the heating season, even if you con gure detailed settings with the temperature low when there is no one in the room and
high when there is someone there, the air conditioning will automatically switch over.
Example of how to set the timer 1
Monday to Friday
Program
Set the ON Timer with a temperature of 74°F for 7:00 AM. Program Set the OFF timer for 9:00 AM.
Program
Set the ON Timer with a temperature of 78°F for 5:00 PM. Program Set the OFF timer for 11:00 PM.
Saturday
Program
~ No timer settings.
Sunday
If you set the OFF Timer for Program
at 9:00 AM, Program at 11:00 AM, Program at 5:00 PM, and Program at 11:00 PM.
Program
7:00 AM ON 74°F
Program
9:00 AM OFF
Program
5:00 PM ON 78°F
Program
11:00 PM OFF
No timer settings
Program
9:00 AM OFF
Program
11:00 AM OFF
Program
5:00 PM OFF
Program
11:00 PM OFF
Monday to
Friday
Saturday
Sunday
Wake up
Leave for work
Come back
home
Go to sleep
ON ON ON ON
Program
7:00 ON 72 °F
Program
9:00 ON 76 °F
Program
17:00 ON 80 °F
Program
23:00 ON 76 °F
9319356051_OM.indb 169319356051_OM.indb 16 12/5/2011 3:25:43 PM12/5/2011 3:25:43 PM