Friedrich XQ10M10 Air Conditioner User Manual


 
HEAT / COOL ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
noitcAesuaC elbissoPmelborP
Room temperature
uneven
(Heating cycle)
Heat anticipator (resistor) shorted (on applicable
models)
Disconnect power to unit. Remove resistor from
t-stat bulb block. Plug in unit & allow to operate.
Feel resistor for heat. If not heat, replace resistor
Wide differential - partial loss of t-stat bulb charge Replace t-stat
Incorrect wiring
Refer to appropriate wiring diagram. Resistor is
energized during "ON" cycle of compressor or
fan.
noitcAesuaC elbissoPmelborP
Does not heat
adequately
Opened doors or windows
Close doors or windows.
Dirty launaM s'renwO ni dednemmocer sa naelCretl
Unit undersized
Check heat rise across coil. If unit operates
ef ciently, check if insulation can be added
to attic or walls. If insulation is adequate,
recommend additional unit or larger one
Heater hi-limit control cycling on & off
Check for adequate fan air across heater. Check
control for open at 110°F & close at 100°F
Shorted or opened heater Ohmmeter/continuity check
margaid gniriw elbacilppa kcehCgniriw tcerrocnI
36
* NOTE: Heater size on the EQ08M11 is: 1.15 KW.
*