Friedrich XQ06M10 Air Conditioner User Manual


 
29 29
Due to variations in room design, climate zone and occupancy, larger areas
may require the use of multiple units to provide the optimal cooling solution.
This is a general guide.
Please consult manual J or M for exact load calculations.
1. If heavily shaded, reduce capacity 10%.
2. If very sunny, add 10%.
3. Add 500 BTU/H per person over 2 people.
4. Add 4,000 BTU/H if area is a kitchen.
ROOM AIR CONDITIONER UNIT
PERFORMANCE TEST DATA SHEET
DATE: _______________ MODEL:_______________ SERIAL:________________
YES NO
IS THERE A FRIEDRICH SLEEVE INSTALLED? ____ ____
IS THERE A CHASSIS SEAL GASKET INSTALLED? ____ ____
IS MAINTENANCE BEING PERFORMED? ____ ____
If NO is checked use back of sheet for explanation
ELECTRICAL:
LINE VOLTAGE (STATIC) --------- VOLTS
START UP VOLTAGE --------- VOLTS
AMPERAGE DRAW --------- AMPS (COOL)
AMPERAGE DRAW --------- AMPS (HEAT)
COMPRESSOR
LOCKED ROTOR AMPS --------- AMPS
RUNNING AMPS --------- AMPS
LOCKED ROTOR VOLTAGE --------- VOLTS
INDOOR TEMPERATURES:
INDOOR AMBIENT TEMPERATURE -------- F
RELATIVE HUMIDITY (RH) INDOOR -------- %
COOL HEAT
DISCHARGE AIR TEMPERATURE (INDOOR) ---------- F --------- F
RETURN AIR TEMPERATURE (INDOOR) ---------- F --------- F
DIFFERENTIAL ---------- F --------- F
OUTDOOR TEMPERATURE:
OUTDOOR AMBIENT TEMPERATURE --------- F
RH OUTDOOR --------- %
CONDENSER:
DISCHARGE AIR TEMPERATURE (OUTDOOR) --------- F ---------- F
INTAKE AIR TEMPERATURE (OUTDOOR --------- F ---------- F
DIFFERENTIAL --------- F ---------- F
APPLICATION USE ------------------------- ROOM (RESIDENTIAL OR COMMERCIAL)