Friedrich XQ05M10 Air Conditioner User Manual


 
PERFORMANCE DATA
*
Installation Information / Sleeve Dimensions
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
Circuit Rating/ Breaker
(B)
(C)
Front
SIDE VIEW
Model
Circuit Rating
Breaker or
T-D Fuse
Plug
Face
(NEMA#)
Power Cord
Length (ft.)
Wall Outlet
Appearance
XQ05M10
*
, XQ06M10
*
,
XQ08M10
*
, XQ10M10
*
EQ08M11
*
7
125V - 15A 5 - 15P 6
Sleeve Height Width
Depth
with Front
Shell Depth to
Louvers
Minimum
Extension
Into Room*
Minimum
Extension
Outside*
Window Width
Thru-the-wall Installation
Finished Hole
Minimum** Maximum Height Width Max. Depth
Q 14"
19
¾
"
21
3
/8
"
8
½"
5
½"
10
¾"
22" 42" 14 ¼" 20" 8 ½”
All models use
environmentally
friendly R-410A
refrigerant.
R-410A
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
() models
meet the ENERGY STAR
®
Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh.
† The estimated yearly operating cost of this model was not available at the time the range was published.
Model
Cooling
Capacity Btu
Heating
Capacity Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts COP
Energy
Ratio
EER
Estimated
Yearly
Operating
Cost
Moisture
Removal
Pints/HR
Room Side
Air
Circulation
CFM Sleeve
Net
Weight
Lbs
XStar ®
XQ05M10
*
5500 115 4.5 491 11.2 $39 1.0 170 Q 72
XQ06M10
*
6000 115 4.9 500 12.0 1.0 175 Q 72
XQ08M10
*
7500 115 6.9 701 10.7 $56 1.7 175 Q 71
XQ10M10
*
9500 115 9.0 970
9.8 $56 2.5 180 Q 71
XStar ®
Electric Heat
EQ08M11
*
7500 4000 115 6.3 701 11.2 1290 2.8 10.7 $56 1.9 175 Q 72
Window Mounting Kits
Heat/Cool Models Kit No.
EQ08M11
*
WIKQ
Friedrich heat/cool models include accessories for
thru-the-wall installation only. Window mounting requires
use of optional accessory kit as listed above.
6
COOLING
PERFORMANCE DATA**
EVAP. AIR TEMP. DEG. F
CONDENSER
TEMPERATURE DEG. F
Discharge Temp Suction Temp Super Heat Sub-Cooling
OPERATING PRESSURES ELECTRICAL RATINGS
R-410A
REF.
Voltage
BREAKER FUSE
Discharge Air
Temp.
Drop F.
Suction Discharge Amps Cool Amps Heat
Locked Rotor
Amps
Charge in
OZ.
60 Hertz Amps
Q-Chassis
XQ05M10
*
57 23 117 133 60 5 19 157 410 4.5 24.0 27.0 115 15
XQ06M10
*
54 26 120 152 63 12 18 150 410 4.9 25.0 21.0 115 15
XQ08M10
*
51 29 119 160 63 13 25 138 420 6.3 32.0 25.5 115 15
XQ10M10
*
47 33 131 176 59 12 32 132 490 9.8 57.0 24.0 115 15
EQ08M11
*
49 31 120 162 60 14 27 133 420 7.0 7.6 32.0 25.5 115 15
** Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity, all systems use R410A.
*
Due to continuing research in new energy-saving technology, performance data and 8th and 9th character are subject to change without notice.