Friedrich UE10 Air Conditioner User Manual


 
12
Parts and Installation
INSTALLATION
Pick a location which will allow the conditioned air
to blow into the area you want. Good installation
with special attention to the proper position of the
unit will lessen the chance that service will be
needed.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard
unused parts
HOW TO INSTALL
Before installing the unit, identify the existing
wall sleeve from the list below.
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition
and have a rear grille that securely attaches to
sleeve, or rear flange that serves as a stop for the
Air Conditioner.
Remove old air conditioner from existing wall
sleeve.
Clean the interior of an existing sleeve.
(Do not disturb seals or gaskets.)
Wall sleeve must be securely fastened in wall
before installing the air conditioner. Use the
nails or screws through sleeve into wall, if
needed. Repaint sleeve if needed.
Prepare the wall sleeve for installation of the unit.
If you plan to use your existing wall sleeve, and it
is not FRIEDRICH, use procedure B or C below.
Install new unit into wall sleeve.
CAUTION: When installation is completed,
replacement unit MUST have a rearward slope as
shown. To achieve 1/4" slope, remove the backing
from the 11-13/16" shim strips and attach them as
shown below in Fig. 3. Place the higher portion of
shim to the front of the rib on base of wall sleeve.
1
2
3
4
5
6
1/4"
Wall Sleeve
FRONT
UNIT
SHIM PLACEMENT UNIT INSTALLATION
1" high
3
/
4
" High
Shim
6" 6"
FIG. 3
Installing the FRIEDRICH USC sleeve ensures
optional performances of the unit.
If you decide to keep the existing wall sleeve, you
have to redirect the louvers at the back of the wall
sleeve. Refer to FIG. 8 on p14. The use of pliers is
recommended. If you DO NOT redirect, you run
the risk of poor performance or premature product
failure. This is not covered under the terms of the
FRIEDRICH warranty.
CAUTION
Wall Sleeve Dimensions (inches)
Brand
Width Height Depth
White-Westinghouse
25-1/2 15-1/4
16, 17-1/2
Frigidaire
or 22
Carrier (52F series)
General Electric
26 15-5/8 16-7/8
/Hotpoint
Whirlpool 25-7/8 16-1/2
17-1/8
or 23
Fedders/Emerson
27 16-3/4
16-3/4
Friedrich WSC or 19-3/4
FRIEDRICH USC 25-7/8 15-17/32 16-23/32
Emerson/Fedders 26-3/4 15-3/4 15
Carrier (51S Series) 25-3/4 16-7/8 18-5/8
Procedure Brand
Depth(inches)
A(page 13)
FRIEDRICH USC 16-23/32
White-Westinghouse
Frigidaire Carrier
16, 17-1/2
(52F series)
or 22
General Electric
16-7/8
/Hotpoint
Whirlpool 17-1/8 or 23
Carrier (51S series)
18-5/8
Fedders/Emerson 16-3/4
Friedrich WSC or 19-3/4
Emerson/Fedders 15
B
(pages 14~15)
C
(pages 16~17)
ITEM
DIMENSIONS(inches)
Qty.
Plastic grille 26
3
/
4
x 16
1
/
2
1
Horizontal Insulation Strips
1
3
/
8
x
5
/
8
x 27
3
/
16
1
1
3
/
8
x 1
3
/
8
x 27
3
/
16
1
Around Insulation Strips
1
3
/
8
x
3
/
4
x 61
1
/
2
1
1
3
/
8
x 1
3
/
8
x 61
1
/
2
1
Support Block 1
3
/
4
x 1
3
/
8
x 4
5
/
16
2
Baffle
14 x
4
1
/
2
x
1
/
8
1
Shim 13 x 1 x
3
/
4
2
Trim Frame 2
Washer Screw 4
Nuts(Plastic) 4
Grille Rear 1