Friedrich SS12N10* Air Conditioner User Manual


 
30
REPLACING THE INDOOR COIL
THERMISTOR
REPLACING THE CONTROL BOARD
ELECTRIC SHOCK HAZARD
WARNING
Disconnect power to the unit before
servicing. Failure to follow this warning
could result in serious injury or death.
Remove the decorative front cover (see page 29).
Remove all indicated screws below (8 total, see gure
below). Remove the Discharge Sensor and the User
Interface plugs from the control board.
Remove the decorative front cover (see page 29).
Disconnect discharge sensor plug (red)
Disconnect the User Interface plug (white)
Remove the 3 screws indicated below.
Pull control board and mount plate out and disconnect
the following connectors from it:
Power, capacitor, thermistors, fan, reversing valve
and heater.
Remove the hex screw holding the control board to
its mount plate. Pull out the control board (see gure
below).
Replace the indoor coil sensor. Ensure to properly clip
and insulate it at the same location (see gure below).
Remove the screws indicated at the side and back plate
(6 total, see gure below). Partially lift the top cover and
at the same time carefully swing out from the top, the
back and side plate.
ELECTRIC SHOCK HAZARD
WARNING
Disconnect power to the unit before
servicing. Failure to follow this warning
could result in serious injury or death.
30
Swing
Out
Up