Friedrich SS10N10B Air Conditioner User Manual


 
23
MODEL DESIGNATION CABINET SIZE (H x W x D)
SMALL CHASSIS - SS,
ES, YS
15
15
»
16
" x 25
15
»
16
" x 29" (405 mm x
660 mm x 737 mm)
MEDIUM CHASSIS - SM,
EM, YM
17
15
»
16
" x 25
15
»
16
" x 29" (455 mm x
660 mm x 737 mm)
LARGE CHASSIS - SL,
EL, YL
20
3
»
16
" x 28" x 35
1
»
2
" (513 mm x 711
mm x 851 mm)
Table 3
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
1
2
3
4
65
87
ITEMS NOT TO SCALE
5/16
5/16
1
/4
1
/4
Recommended Tools
1. Power Drill
2. 5/32" Drill Bit
3. Gloves
4. Carpenters Level
5. 5/16" Wrench
6. 1/4" Wrench
7. #2 Phillips Screw Driver
8. Putty Knife or (wood stir stick)
CAUTION
Excessive Weight Hazard
Use two or more people when
installing your air conditioner.
Failure to do so can result in
back or other injury.
WARNING
MOVING PARTS HAZARDS
* Do not operate unit out of sleeve
or with front grille removed.
* Do not place hands in blower or
fan blade areas.
Failure to do so can result in
serious injury.
Installation Instructions
READ THIS FIRST! Electrical Requirements
IMPORTANT: Before you begin the actual installation of your air
Your air conditioner must be connected to a power source with the same
alternating current (A.C.) voltage and amperage as marked on the name
plate located on the chassis. Only A.C. can be used. Direct Current (D.C.)
cannot be used.
CIRCUIT PROTECTION – Use on single outlet circuit o
nly. An overloaded
circuit will invariably cause malfunction or failure of an air conditioner,
therefore, it is necessary that the electrical protection is adequate. Due
to momentary high current demand when the air conditioner starts, use a
"TIME DELAY" fuse or a HACR type circuit breaker. Consult your dealer
or power company if in doubt.
Refer to the electrical name plate located on the air conditioner chassis
(See
page 2) to determine the correct fuse or circuit breaker amperage
for your model (See Table 1 on Page 6 for electrical receptacle types).
The power cord has a plug with a grounding prong and a matching
receptacle is required.
The following instructions are for standard chassis model groups
sizes listed in Table 3.
conditioner, check your local electrical codes and the information below.