Friedrich SS08N10 Air Conditioner User Manual


 
20
FRR080
30°
45°
60°
30°
45°
60°
25ft
25ft
8ft
4ft
25ft
16ft
6ft
30°
30°
45°
60°
45°
60°
25ft
25ft
25ft
8ft
25ft
25ft
7.5ft
SIDE VIEW
TOP VIEW
Figure 11
Remote Control Operation
Remote Control - Refer to Figures 12 and 13 during operation description.
Getting Started - Install two (2) AAA batteries in the battery compartment
located on the back of the unit.
Operation - The remote control should be within 25 feet of the air
conditioner for operation. (Refer to Figure 11 for effectiveness). Press the
power button to turn the remote on. The remote will automatically power
off aft
er 15 seconds if the buttons are not being pressed. The remote must
be on to control the unit.
POWER Button - Turns remote and unit on and off.
SYSTEM Button - Allows the user to sequentially select the
,
HEAT
, and FAN ONLY
following: AUTO - AUTO -, COOL
operations. When the button is pressed, the display indicates which mode
has been selected via a display message.Note that when the heating
automatically skip the HEAT mode.
FAN MODE Button - Selects between automatic (
AUTO FAN
) or
CONTINUOUS
operation. In the
AUTO FAN
mode, the fan only turns on and off when the
compressor operates or the heat function is enabled.
NOTE:
AUTO FAN
is not available in the FAN ONLY Mode, the display
indicates
CONTINUOUS
. In the
CONTINUOUS
mode, fan speed is
determined by your selection on the
FAN
SPEED
button.
FAN SPEED Button - Used to sequentially select new fan speed, plus
AUTO operation. When the
FAN
SPEED
button is pressed, the fan speed icon
(triangle) changes to indicate the new speed level. Fan speed automatically
varies depending on the set temperature on the control panel and the actual
room temperature. For example if there is a big difference between your
set temperature and the actual room temperature, the system fan speed
increases to HIGH. It remains at this speed until the room temperature
matches the set temperatur
e.
SCHEDULE Button – The
SCHEDULE
button turns the schedule function
on and off. Press the Schedule button once to turn on the Schedule
(Residential, Commercial, Timer, or Customized) that has already been
selected on your unit. Pressing the
SCHEDULE
button a second time turns
the schedule function off.
UP and DOWN Arrows - Pressing either the
(UP) or (DOWN)
button changes the desired room temperature. The factory preset lower
and upper limits are 60°F (16°C) and 99°F (37°C). These buttons are also
used to navigate between function options when using the User Menu or
Maintenance Mode.
Remote Effectiveness
Hand Held Remote - Has an operating range of up to 25 ft. The infrared
remote control signal must have a clear path to transmit the command to
the air conditioning unit. The
remote signal has some ability to "bounce"
off of walls and furniture similar to a television remote control. The diagram
below shows the typical operating range of the control in a standard room
with 8 ft high ceilings.
function is not available, the system will
Service Questions: Contact Friedrich at (800) 541-6645
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com