Friedrich SP08A10 Air Conditioner User Manual


 
Disassembly and Reassembly Procedure(SP10A10/SP12A10)
No. Part Name Procedures Remarks
4
Plate reinf&
Case evap up
1..Remove 4 screws on the partition and case
cond.
2.Remove the plate reinf. (The shape maybe
different depend on models)
3.Remove the seal sticked on the case evap up
carefully.
4.Pull the case evap up upward.
5 Plate evap
casing &
Blower
1.Remove the cover on the evaporator.
2.Remove all screws on the evaporator.
3.Pull the evaporator forward carefully.
4.Remove all screws fixed on plate evap
casing, then pull it out completely.
3.Remove the nut and remove the Blower.
6 Case Cond &
Fan Propeller
& Motor Fan
1.Remove 2 screws on the rear side of the
base pan, and all screws fixed on case cond.
2.Pull up the condenser from the base pan.
3.Remove the nut and remove the Propeller
fan.
4.Remove 4 screw(fixed on the mounter ), then
take out the motor.
4-4 FRIEDRICH AIR CONDITIONING CO.