Friedrich Room Air Conditioners Air Conditioner User Manual


 
Model
Circuit Rating
Breaker or
T-D Fuse
Plug Face
(NEMA#)
Wall Outlet
Appearance
SS08L10, SS10L10, SS12L10 and SS14L10.
125V - 15A 5 - 15P
SS12L30, SS16L30, SM18L30A and SM21L30.
250V - 15A 6 - 15P
SM24L30 and SL28L30
250V - 20A 6 - 20P
Installation Information / Sleeve Dimensions
Circuit Rating/ Breaker
The consumer- through the AHAM Room Air Conditioner Certification Program- can be certain that the AHAM Certification Seal accurately
states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.
Specications
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
() models meet the ENERGY STAR
®
guidelines for energy efficiency.
ENERGY STAR
®
Models
Sleeve Height Width
Depth
with Front
Depth
Hood to
Louvers
Minimum
Extension
Into Room
Minimum
Extension
Outside
Window Width
Thru-the-wall
Finished Hole
Minimum Maximum Height Width
S 15
15
16" 25
15
16" 27
3
8" 8 ¾" 3
1
16" 16
15
16" 27
7
8" 42" 16
3
16" 26
3
16"
M 17
15
16" 25
15
16" 27
3
8" 8 ¾" 3
1
16" 16
15
16" 27
7
8" 42" 18
3
16" 26
3
16"
Cooling
Capacity
BTU/h
Heating
Capacity
Rated
Electrical Characteristics (60 Hertz)
Energy
Efficiency
Ratio
EER
Moisture
Removal
Pints/Hr.
Room Side
Air Circulation
CFM Sleeve*
Net
Weight
Lbs. Model
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
COMMERCIAL GRADE
QUIETMASTER Programmable
SS08L10 8400 115 6.6 737 11.4 1.6 265 S 108
SS10L10 10400 115 7.5 867 12.0 2.5 260 S 115
SS12L10 11800 115 9.0 1000 11.8 2.5 350 S 114
SS14L10 14000 115 12.0 1305 10.7 3.5 377 S 128
SS12L30 12100/11900 230/208 4.8/5.0 1052/1017 11.5/11.7 2.9 320 S 114
SS16L30 16200/15900 230/208 7.4/8.0 1653/1656 9.8/9.6 4.7 360 S 119
SM18L30A 17500/17300 230/208 7.2/7.7 1620/1570 10.8/10.8 4.5 375 M 163
SM21L30 20600/20200 230/208 9.4/10.1 2081/2020 9.9/10.0 6.0 425 M 154
SM24L30 23500/23000 230/208 11.2/12.1 2479/2421 9.5/9.5 7.0 400 M
154
Friedrich room air conditioners are designed to operate in outdoor temperatures from 50°
F to 115°
F.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.